The Wheeled Mobility Anthropometry Project recommends this platform dimension.iv These study findings noted that a 36-inch length accommodates standard manual and power wheelchairs and most...
Search Results "Wheelchair Scale"
-
5.8.1.1 Clear Platform Size Recommendation
-
Permitted Protrusions in Wheelchair Spaces: ADA Standard Section 1002.4.4.3
Objects are permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum...
-
Tips for Weighing People Using an Accessible Scale
Scale Placement Wheelchair scales require 2x the (straight-route) length of the scale for a wheelchair or scooter user to enter and exit....
-
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations
The protection stops the mobility device from driving off either side of the platform. 5.8.1.2.3 Double Ramp Scale with Edge Protection (SOURCE: U.S. Access Board)...
-
Observations:
The wheelchair scale we used had a leveled surface of length 30 in. long with a bevel of 5 in. each at both ends (i.e., total length of 40 in.)....
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
M303.1 General (Section-by-Section Analysis)
This is an introductory section.
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
The limitation on edge protection height will reduce the possibility that the edge protection will interfere with the patient’s footrest. 5.8.1.2.2 Single Ramp Scale with Edge Protection...
-
M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
[See subsections ...]
-
M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
[See subsections ...]
- AquaTrek2 AQ-250PC Aquatic Wheelchair
- AquaTrek2 AQ-350 Aquatic Wheelchair
-
11B-802.1 Wheelchair spaces
Wheelchair spaces shall comply with Section 11B-802.1....
-
11B-802.1 Wheelchair spaces
Wheelchair spaces shall comply with Section 11B-802.1....
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.
-
M303.3.3.3 Clear Width