Wheelchair spaces shall be designed so that a patient seated in a wheelchair orients in the same direction that a patient not seated in a wheelchair orients when the diagnostic...
Search Results "Weight Scale"
-
M303.2.1 Orientation
-
M303.2.1 Orientation
Wheelchair spaces shall be designed so that a patient seated in a wheelchair orients in the same direction that a patient not seated in a wheelchair orients when the diagnostic...
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum.
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum. EXCEPTION: Wheelchair spaces located on raised platforms shall be permitted to be 32 inches (815 mm) wide minimum to a...
-
M303.2.3 Depth
The depth of wheelchair spaces shall comply with M303.2.3.
-
M303.2.3 Depth
Where wheelchair spaces can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where wheelchair spaces can be entered only from the...
-
M303.2.3.1 Front or Rear Entry
Where wheelchair space entry and exit is provided at only one end (front or rear) the wheelchair space shall be 48 inches (1220 mm) deep minimum.
-
M303.2.3.2 Pass Through Entry
Where wheelchair space entry and exit permits pass through from one end to the other, the wheelchair space shall be 40 inches deep (1015 mm) minimum.
-
M303.2.3.3 Side Entry
Where wheelchair space entry is only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum.
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
M303.2.6 Edge Protection
Where wheelchair spaces are provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the...
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
M303.3 Entry
Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3.
-
M303.3 Entry
Where there is a change in level at the entry to a wheelchair space, the change in level shall comply with M303.3.
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.