Panda Windows & Doors TS.87 lift and slide profile thermally broken corner sample built for the custom luxury sliding door market....
Search Results "Water Slide"
Commonly Searched Documents
- Panda TS.87 Lift & Slide Slim Profile Thermally Broken Corner Sample
- Panda TS.13 Aluminum/Wood Clad Thermally Broken Lift & Slide System
-
Transfer Steps: ADA Standard Section 1009.5.4
The surface of the bottom tread shall extend to a water depth of 18 inches (455 mm) minimum below the stationary water level. Advisory 1009.5.4 Transfer Steps....
-
11B-1009.2.1 Pool lift location
Pool lifts shall be located where the water level is 36 inches (914 mm) minimum and 48 inches (1219 mm) maximum. [2010 ADA Standards] 1009.2.1 Pool Lift Location....
-
Water Coolers
The proposed rule scoped both drinking fountains and water coolers....
-
Pool Lift Location: ADA Standard Section 1009.2.1
Pool lifts shall be located where the water level does not exceed 48 inches (1220 mm). EXCEPTIONS: 1....
-
Overlap: ADA Standard Section 604.3.2
Section 604.3.2 covers the current ADA Standards for overlapping clearances in the water closet clear floor space.
-
Water closet
Water closet Increased sidewall space adjacent to toilet....
-
11B-604 Water closets and toilet compartments
[See subsections ...]
- Kawneer North America 1010C Sliding Mall Front
- Panda S.81 All Aluminum Multi-Slide Door System
- Panda S.90 All Aluminum Slim Profile Multi-Slide Door System
- Panda TS.83 Thermally Broken Multi-Slide Door System
- Nana Wall Systems, Inc. Sliding Glass Walls HSW60 Video
- Panda S.65 All Aluminum with Aluminum/Wood Clad Multi-Slide Door System
-
Water Closet Centerline and Seat Height
Water closets are to be located so that the centerline is 16 to 18 inches from the side wall compartment partition (604.2)....
-
Seats: ADA Standard Section 604.4
Section 604.4 covers the current ADA Standards for the water closet seats.
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section....
-
213.3.2 Water Closets
213.3.2 Water Closets. Where water closets are provided, at least one shall comply with 604....
- Kawneer North America 1010 Sliding Mall Front
-
Flush Controls: ADA Standard Section 604.9.5
Section 604.9.5 covers the current ADA Standards for flush controls on children's use water closets.
-
Water Closets [4.16]
Water Closets [4.16] Accessible water closets, including those located in stalls, must comply with the requirements in 4.16....
-
Location: ADA Standard Section 604.9.1
Section 604.9.1 covers the current ADA Standards for the mounting location of children's use water closets.
- Kawneer North America 1040 Sliding Mall Front Door