A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
Search Results "Transfer Access"
Commonly Searched Documents
-
1009.5.2 Transfer Space
-
1009.5.1 Transfer Platform
A transfer platform shall be provided at the head of each transfer system....
-
1009.5.1 Transfer Platform
A transfer platform shall be provided at the head of each transfer system....
-
1014.2 Entrance
This section requires camp shelters to provide either transfer access or roll-in access at the entrance to the camp shelter....
-
Entrance [1014.2]
Camp shelters must provide either transfer access or roll-in access at the entrance....
-
Height: ADA Standard Section 1009.5.3
The height of the transfer platform shall comply with 1009.4.2....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
Surface: ADA Standard Section 1009.4.4
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
Surface: ADA Standard Section 1009.5.5
The surface of the transfer system shall not be sharp and shall have rounded edges....
-
11B-1009.5.5 Surface
The surface of the transfer system shall not be sharp and shall have rounded edges....
-
11B-1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.1 Transfer platform
A transfer platform shall be provided at the head of each transfer system....
- Quadraplegic Transfer
-
Transfer Heights
Thus adjustability, including this range, would include all of the study participants and allow for greater accessibility where transfers are needed. 5....
-
Height: ADA Standard Section 1009.4.2
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
Ground Level and Elevated Play Components: ADA Standard Section 1008.2.1
Accessible routes serving ground level play components and elevated play components shall be permitted to use the exceptions in 1008.2.1. EXCEPTIONS: 1....
-
11B-1008.2.1 Ground level and elevated play components
Accessible routes serving ground level play components and elevated play components shall be permitted to use the exceptions in Section 11B-1008.2.1....
-
11B-1009.5.1 Transfer platform
A transfer platform shall be provided at the head of each transfer system....
-
11B-1009.5.1 Transfer platform
A transfer platform shall be provided at the head of each transfer system....
-
M302.2.5 Unobstructed Transfer
Each transfer side complying with M302.2.4 shall provide unobstructed access to transfer surfaces. EXCEPTIONS: 1....