Search Results "Parallel Approach"
-
305.5 Position
-
11B-809.9.1 Clear floor space
approach at the range....
-
11B-809.9.1 Clear floor space
approach at the range....
-
11B-305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. ...
-
Side Approach and Reach
[See subsections ...]
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Power Chair
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching...
-
4.34.2 Clear Floor Space
The automated teller machine shall be located so that clear floor space complying with 4.2.4 is provided to allow a person using a wheelchair to make a forward approach, a parallel approach...
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
The 1991 Standards, at section 4.24, and the 2010 Standards, at section 606, both require the clear floor space at sinks to be positioned for a forward approach and knee and toe clearance...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
Forward Approach: ADA Standard Section 904.4.2
A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
Side Approach
Side Approach Where space is provided for a side approach, controls can be mounted at the heights allowed for side reaches....
-
Side Approach
Side Approach Side reach depth is important to consider in the design and location of sinks....
- Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach – Drawing from the U.S. Access Board
-
Side Approach
Side Approach The maximum reach depth for a high (54 inch maximum) reach is 10 inches, measured from the clear floor space....
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
- Access Board: Parallel Approach at an Alcove