4.15.2* SPOUT HEIGHT
Figure 27 Drinking Fountains and Water Coolers...
-
11B-602.5 Spout location
FIGURE 11B-602.5 DRINKING FOUNTAIN SPOUT LOCATION...
-
602.5 Spout Location
[ECTCR UFAS 4.15.3] Figure 602.5 Drinking Fountain Spout Location...
-
602.5 Spout Location
Figure 602.5 Drinking Fountain Spout Location...
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
11B-602.1 General
Drinking fountains shall comply with Sections 11B-307 and 11B-602....
-
11B-602.1 General
Drinking fountains shall comply with Sections 11B-307 and 11B-602....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
Dispersion
Dispersion Recommendation: Wheelchair accessible units and standard units should be evenly dispersed to maximize convenient availability. For example, if a floor is occupied by...
-
4.15.3 Spout Location
The spouts of drinking fountains and water coolers shall be at the front of the unit and shall direct the water flow in a trajectory that is parallel or nearly parallel to the front of the...
- Halsey Taylor Bi-Level Barrier-Free Cooler
- ELKAY EZH2O® Bottle Filling Station with Integral SwirlFlo® Fountain EZWS-EDFPBM117K
-
R212.2 Drinking Fountains
R212.2 Drinking Fountains. Drinking fountains shall comply with sections 602.1 through 602.6 of Appendix D to 36 CFR part 1191....
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....