In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
Search Results "First Occupancy"
Commonly Searched Documents
-
1018.5 Aisles in other than assembly spaces and Groups B and M
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
§100.301(b)
(b) Nothing in this part limits the applicability of any reasonable local, State, or Federal restrictions regarding the maximum number of occupants permitted to occupy a dwelling....
-
24 CFR Part 100—Supplement to Notice of Fair Housing Accessibility Guidelines: Questions and Answers about the Guidelines
comply with the accessibility requirements of the Fair Housing Amendments Act of 1988 (Fair Housing Act) that are applicable to certain multifamily dwellings designed and constructed for first...
-
1007.6.1 Size
Each area of refuge shall be sized to accommodate one wheelchair space of 30 inches by 48 inches (762 mm by 1219 mm) for each 200 occupants or portion thereof, based on the occupant load...
-
1003.2.13.5.1 Size
Each area of refuge shall be sized to accommodate one wheelchair space of 30 inches (762 mm) by 48 inches (1219 mm) for each 200 occupants or portion thereof, based on the occupant load...
-
11B-405.5 Clear width
The clear width of ramps in residential uses serving an occupant load of fifty or less shall be 36 inches (914 mm) minimum between handrails....
-
§ 38.23(b)(1) Design load
(1) Design load. The design load of the lift shall be at least 600 pounds. Working parts, such as cables, pulleys, and shafts, which can be expected to wear, and upon which the lift...
-
406.2.3 Accessible parking spaces
Where parking is provided, accessible parking spaces, access aisles and vehicular routes serving accessible parking shall be provided in accordance with Chapter 11A.
-
§100.205(c)
(c) All covered multifamily dwellings for first occupancy after March 13, 1991 with a building entrance on an accessible route shall be designed and constructed in such a manner that—...
-
1007.6.1 Size
The total number of such 30-inch by 48-inch (762 mm by 1219 mm) spaces per story shall be not less than one for every 200 persons of calculated occupant load served by the area of refuge...
-
1009.6.3 Size
The total number of such 30-inch by 48-inch (762 mm by 1219 mm) spaces per story shall be not less than one for every 200 persons of calculated occupant load served by the area of refuge...
-
1009.6.3 Size
The total number of such 30-inch by 48-inch (762 mm by 1219 mm) spaces per story shall be not less than one for every 200 persons of calculated occupant load served by the area of refuge...
-
Sec.36.401(a)(2)(i)
(i) If the last application for a building permit or permit extension for the facility is certified to be complete, by a State, County, or local government after January 26, 1992...
-
§ 36.401(a)(2)(i)
(i) If the last application for a building permit or permit extension for the facility is certified to be complete, by a State, County, or local government after January 26, 1992...
-
Diversion and Coordination with Mental Health Providers
Diversion and Coordination with Mental Health Providers: A settlement agreement in Portland led to the creation of a crisis center available to first responders seeking to divert individuals...
-
ENSURING LANGUAGE ACCESS AND EFFECTIVE COMMUNICATION DURING RESPONSE AND RECOVERY: A CHECKLIST FOR EMERGENCY RESPONDERS
Allocate at least double the time of a regular interview During the Interpretation Look at and speak directly in the first person to the LEP individual...
-
Section 3. Fair Housing Act Design and Construction Requirements
ETA Editor's Note Section 3 of the original document reprints the text of 24 CFR §100.205, which implements the Fair Housing Act's accessibility requirements. However, the...
-
907.2.1 Group A
A manual fire alarm system shall be installed in accordance with NFPA 72 in Group A occupancies having an occupant load of 300 or more....
-
907.2.3 Group E
A manual fire alarm system shall be installed in Group E occupancies....
-
907.2.4 Group F
A manual fire alarm system shall be installed in Group F occupancies that are two or more stories in height and have an occupant load of 500 or more above or below the lowest level of exit...
-
907.2.2 Group B
A manual fire alarm system shall be installed in Group B occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
4.3.1 Overview of Imaging Equipment and Regulatory Environment
An Occupational Safety and Health Administration (OSHA) credentialed Nationally Recognized Testing Laboratory must test and certify the equipment to demonstrate that it meets the basic safety...
-
11B-405.5 Clear width
The clear width of ramps in residential uses serving an occupant load of fifty or less shall be 36 inches (914 mm) minimum between handrails. [2010 ADAS] 405.5 Clear Width....