With destination-oriented elevators, passengers indicate the floor destination when calling an elevator, usually through a keypad....
Search Results "Elevator Hall Signal"
Commonly Searched Documents
-
Destination-Oriented Elevators
-
Door and Signal Timing
Section 407.3.4 specifies door and signal timing....
-
11B-407.2.1 Call controls
Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4. [2010 ADA Standards] 407.2.1 Call Controls....
-
Elevator Door Requirements [§407.3]
Elevator Door Requirements [§407.3]...
-
11B-411.2.1.1 Location
Hall call consoles shall be wall-mounted. On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same...
-
11B-407.2.1.2 Size and shape
[2010 ADA Standards] EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
Section I: Elevators
(§§407.4.6.1, 308.2, 308.3) I5 Does the elevator have visible and audible signals in the hallway to indicate the arrival and direction of...
-
Keypads: ADA Standard Section 407.2.1.6
Section 407.2.1.6 covers the current ADA Standards for elevator keypads.
-
Height: ADA Standard Section 407.2.1.1
Section 407.2.1.1 covers the current ADA Standards for the height of the elevator call controls.
-
11B-411.2.1.5.2 Color
Characters and symbols on buttons, where provided, shall be white on a black background.
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
-
Elevator Landing Requirements [§407.2]
Elevator Landing Requirements [§407.2]...
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5....
-
4.10.7* Door and Signal Timing for Hall Calls
For cars with in-car lanterns, T begins when the lantern is visible from the vicinity of hall call buttons and an audible signal is sounded....
-
4.10.7* DOOR AND SIGNAL TIMING FOR HALL CALLS
For cars with in-car lanterns, T begins when the lantern is visible from the vicinity of hall call buttons and an audible signal is sounded....
-
Audible Tones/Bells or Verbal Annunciators
...are all of the elevators equipped with audible tones/bells or verbal annunciators that designate the passage of floors?...
-
Signal-to-Noise Ratio: ADA Standard Section 706.5
The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum....
-
11B-407.2.1.6 Keypads
ETA Editor's Note Lacking certain Exceptions allowed by 2010 ADA Standards, and imposing additional requirements regarding call buttons, the preceding CBC requirements pertaining to elevator...
-
A4.10.7 Door and Signal Timing for Hall Calls
This paragraph allows variation in the location of call buttons, advance time for warning signals, and the door-holding period used to meet the time requirement....
-
A4.10.7 DOOR AND SIGNAL TIMING FOR HALL CALLS
This paragraph allows variation in the location of call buttons, advance time for warning signals, and the door-holding period used to meet the time requirement....
-
11B-411.2.1.3 Arrangement
Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3....
-
11B-411.2.1.4 Additional features
Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4....