No fewer than two drinking fountains shall be provided....
Search Results "Drinking Fountain"
-
11B-211.2 Minimum number
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
A4.15.2
Drinking fountains with two spouts can assist both handicapped people and those people who find it difficult to bend over....
-
A4.15.2 Spout Height
Two drinking fountains, mounted side by side or on a single post, are usable by people with disabilities and people who find it difficult to bend over....
-
A4.1.3(10)
A4.1.3(10) If an odd number of drinking fountains is provided on a floor, the requirement in 4.1.3(10)(b) may be met by rounding down the odd number to an even number and calculating 50%...
-
4.15.2* SPOUT HEIGHT
Figure 27 Drinking Fountains and Water Coolers...
-
4.1.3(10)(a)
(a) Where only one drinking fountain is provided on a floor there shall be a drinking fountain which is accessible to individuals who use wheelchairs in accordance with 4.15 and one accessible...
-
One Unit Per Floor
Cup dispensers at fixed units are not recommended but if provided for dual access, the drinking fountain should be wheelchair accessible....
-
11B-602.5 Spout location
FIGURE 11B-602.5 DRINKING FOUNTAIN SPOUT LOCATION...
-
602.5 Spout Location
[ECTCR UFAS 4.15.3] Figure 602.5 Drinking Fountain Spout Location...
-
602.5 Spout Location
Figure 602.5 Drinking Fountain Spout Location...
-
4.1.3(10)(b)
(b) Where more than one drinking fountain or water cooler is provided on a floor, 50% of those provided shall comply with 4.15 and shall be on an accessible route....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
F211 Drinking Fountains
[See subsections ...]
-
602 Drinking Fountains
[See subsections ...]
-
602 Drinking Fountains
[See subsections ...]
-
4.1.2(9)
(9) If drinking fountains or water coolers are provided, approximately 50 percent of those provided on each floor shall comply with 4.15 and shall be on an accessible route....
-
211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with 211....
-
211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with 211....
-
F211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with F211....
-
F202.6.5.1 Drinking Fountains
Drinking fountains shall comply with F211....
-
6) Water fountains
6) Water fountains ADAAG: Where there is more than one fountain on a floor, 50% must be accessible to persons using wheelchairs....