Section 602.4 covers the current ADA Standards for the spout height of drinking fountains.
Search Results "Counter Height"
-
Spout Height: ADA Standard Section 602.4
-
B. Question 2: Section 904.4.1 and Clear Counter Space
An entity does not violate the length requirement, where applicable, when it “maintain[s] merchandise or other items on the counter top, thereby failing to maintain 36-inches of clear counter...
-
902.4.2 Height
902.4.2 Height. The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground....
-
Check-Out Aisles and Sales and Service Counters: ADA Standard Section 904
[See subsections ...]
-
B. The ADA Standards for Accessible Design
for sales and service counters....
-
Approach: ADA Standard Section 904.2
All portions of counters required to comply with 904 shall be located adjacent to a walking surface complying with 403. Advisory 904.2 Approach....
-
11B-904.2 Approach
All portions of counters required to comply with Section 11B-904 shall be located adjacent to a walking surface complying with Section 11B-403. Advisory 11B-904.2 Approach....
-
11B-904.2 Approach
All portions of counters required to comply with Section 11B-904 shall be located adjacent to a walking surface complying with Section 11B-403. Advisory 11B-904.2 Approach....
-
Cubicles and Counters: ADA Standard Section 231.4.1
Section 231.4.1 covers scoping requirements in the current ADA Standards for cubicles and counters.
-
11B-904 Check-out aisles and sales and service counters
[See subsections ...]
-
11B-904 Check-out aisles and sales and service counters
[See subsections ...]
-
902.3 Height
902.3 Height. The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
7.3(2)
(2) Clear aisle width for accessible check-out aisles shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 38 in (965 mm) above the finish floor....
-
Q1.) When a ramp has a maximum slope of 1:12 or 8.33%, is that considered a range of from 0% to 8.33% which would allow no slope greater than 8.33% or is that a simple maximum which would allow a tolerance above 8.33%? Similarly, is a cabinet countertop that can be no higher than 34” AFF a range of from 0” to 34” AFF with no additional height allowed, or is a tolerance allowed for variations in the floor surface or cabinet construction?
A1.) The consistent technical assistance on this question has been that both are subject to tolerances.
-
Transfer Height: ADA Standard Section 1002.5.2
The height of amusement ride seats designed for transfer shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
227 and 904 Sales and Service
[See subsections ...]
-
227.3 Counters
227.3 Counters. Where provided, at least one of each type of sales counter and service counter shall comply with 904.4....
-
F227.3 Counters
Where provided, at least one of each type of sales counter and service counter shall comply with 904.4....
-
227.3 Counters
Where provided, at least one of each type of sales counter and service counter shall comply with 904.4....
-
III. CONCLUSION
For the foregoing reasons, neither Section 904.4.1 nor its exception requires clear counter space at sales and service counters subject to the ADA’s requirements....
-
R212.5 Counters
R212.5 Counters. Counters shall comply with section 904 of Appendix D to 36 CFR part 1191....
-
11B-231.4.1 Cubicles and counters
Where counters are provided, at least one shall comply with Section 11B-904.4.2 on both the visitor and detainee sides....