If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
Search Results "Children's Reach Range"
Commonly Searched Documents
-
4.2.5 FORWARD REACH
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
4.2.5* Forward Reach
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
11B-1008.4.2 Clear floor or ground space
The following table provides guidance on reach ranges for children seated in wheelchairs. These dimensions apply to either forward or side reaches....
-
A4.2.5 & A4.2.6 Reach
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a)....
-
4.3.7 Clear Floor Space for Reaching
For forward reaches, the longest reach range will also be at the level of the shoulder unless the individual has an upper extremity impairment that affects range of motion....
-
A4.2.5 & A4.2.6 REACH
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a)....
-
Reach Ranges and Operable Parts
REACH RANGES AND OPERABLE PARTS Forward and side reach 11B-308.2/3 Over projections 11B-308.2.2/3.2...
-
Reach Ranges and Operable Parts
REACH RANGES AND OPERABLE PARTS Forward and side reach 11B-308.2/3 Over projections 11B-308.2.2/3.2...
-
11B-1007.3.2 Golf club reach range area
Advisory 11B-1007.3.2 Golf club reach range area. The golf club reach range applies to all holes required to be accessible....
-
1008.4.2 Clear Floor or Ground Space
When designing play components with manipulative or interactive features, consider appropriate reach ranges for children seated in wheelchairs....
-
11B-1008.4.2 Clear floor or ground space
When designing play components with manipulative or interactive features, consider appropriate reach ranges for children seated in wheelchairs....
-
11B-1008.4.2 Clear floor or ground space
The following table provides guidance on reach ranges for children seated in wheelchairs. These dimensions apply to either forward or side reaches....
-
22.1 Q. Must the switches on range hood kitchen ventilation fans be in accessible locations?
Kitchen ventilation fans located on a range hood are considered to be part of the appliance....
-
Reach Ranges
Reach Ranges. The 1991 Standards set the maximum height for side reach at 54 inches above the floor....
-
Obstructed Reach Depth
Obstructed Reach Depth...