Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
Search Results "Bedside Clearance"
-
11B-505.5 Clearance
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
806.2.3 Sleeping Areas
806.2.3 Sleeping Areas. At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel...
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of...
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of...
-
9.5.2(2)(b)
(b) sleeping space for homeless persons as provided in the scoping provisions of 9.1.2 shall include doors to the sleeping area with a minimum clear width of 32 in (815 mm) and...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
11B-605.5.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side...
-
11B-605.5.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side...
-
11B-306.2 Toe clearance
[See subsections ...]
-
11B-306.3 Knee clearance
[See subsections ...]
-
11B-306.3 Knee clearance
[See subsections ...]
-
11B-306.2 Toe clearance
[See subsections ...]
-
11B-305.4 Knee and toe clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-305.4 Knee and toe clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
F224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3.
-
224.3 Beds
224.3 Beds. In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3.
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space. A clear floor space...
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3.
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed.
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed.
-
224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3.
-
805.3 Clear Floor or Ground Space
805.3 Clear Floor or Ground Space. A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach...