Section 36.304 Removal of Barriers Section 36.304 requires the removal of architectural barriers and communication barriers that are structural in nature in existing facilities, where...
Search Results "Barrier Wall"
Commonly Searched Documents
-
Section 36.304 Removal of Barriers (Preamble, Section-by-Section Analysis)
-
Section 36.304 Removal of Barriers (Section-By-Section Analysis and Response to Comments)
Section 36.304 Removal of Barriers (Section-By-Section Analysis and Response to Comments) Section 36.304 requires the removal of architectural barriers and communication barriers that...
-
Side Wall: ADA Standard Section 604.5.1
Section 604.5.1 covers the current ADA Standards for side wall grab bars that are used for water closets.
-
Security Barriers [§206.8]
Security Barriers [§206.8] Security bollards and screening devices at accessible entrances cannot obstruct accessible routes or accessible means of egress....
-
Architectural Barriers
Architectural Barriers....
-
Examples of Barrier Removal
Examples of Barrier Removal The following examples illustrate common barriers and suggest solutions that may be readily achievable....
-
III-4.4000 Removal of barriers
[See subsections ...]
-
Rear Wall: ADA Standard Section 604.5.2
Section 604.5.2 covers the current ADA Standards for rear wall grab bars that are used for water closets.
-
§ 36.304 Removal of barriers.
[Order No. 1513-91, 56 FR 35592, July 26, 1991, as amended by AG Order No. 3181-2010, 75 FR 56254, Sept. 15, 2010; AG Order No. 3332-2012, 77 FR 30179, May 21, 2012]
-
709.4 Continuity
Smoke barriers shall form an effective membrane continuous from outside wall to outside wall and from floor slab to floor or roof deck above, including continuity through concealed spaces...
-
Spas: ADA Standard Section 242.4
Section 242.4 covers scoping requirements in the current ADA Standards for spas.
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
§ 36.304(b) Examples
Examples of steps to remove barriers include, but are not limited to, the following actions—...
-
11B-404.2.7 Door and gate hardware
Access gates in barrier walls and fences protecting pools, spas, and hot tubs shall be permitted to have operable parts of the release of latch on self-latching devices at 54 inches (1372...
-
11B-404.2.7 Door and gate hardware
Access gates in barrier walls and fences protecting pools, spas, and hot tubs shall be permitted to have operable parts of the release of latch on self-latching devices at 54 inches (1372...
- Figure 1009.4.3 Depth and Length of Tranfer Walls – Drawing from the U.S. Access Board
-
404.2.7 Door and Gate Hardware
Access gates in barrier walls and fences protecting pools, spas, and hot tubs shall be permitted to have operable parts of the release of latch on self-latching devices at 54 inches (1370...
-
404.2.7 Door and Gate Hardware
Access gates in barrier walls and fences protecting pools, spas, and hot tubs shall be permitted to have operable parts of the release of latch on self-latching devices at 54 inches (1370...
-
404.2.7 Door and Gate Hardware
Access gates in barrier walls and fences protecting pools, spas, and hot tubs shall be permitted to have operable parts of the release of latch on self-latching devices at 54 inches (1370...
-
Section 36.304 Removal of Barriers (Section-by-Section Analysis)
The Department expressed concern that requiring barrier removal for incremental changes might place unnecessary cost burdens on businesses that already had removed barriers in existing facilities...
-
Temporary Barrier Removal Suggestions for Accessible Features
Temporary Barrier Removal Suggestions for Accessible Features...
-
607.4.2.2 Control End Wall
607.4.2.2 Control End Wall. A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
607.4.1.2 Control End Wall
607.4.1.2 Control End Wall. A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
607.4.2.3 Head End Wall
607.4.2.3 Head End Wall. A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub. ...