(455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory...
Search Results "Ambulatory Accessible Compartment"
Commonly Searched Documents
-
604.2 Location
-
4.17 Toilet Stalls
[See subsections ...]
-
A4.17 Toilet Stalls
[See subsections ...]
-
4.17 TOILET STALLS
[See subsections ...]
-
A4.17 TOILET STALLS
[See subsections ...]
-
Error/Omission: Toilet rooms with 6 or more toilet stalls lack a 36" wide "ambulatory" toilet stall.
Error/Omission: Toilet rooms with 6 or more toilet stalls lack a 36" wide "ambulatory" toilet stall....
-
604.2 Location
(455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory...
-
604.2 Location
(455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory...
-
604.9.1 Location
(455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory...
-
604.9.1 Location
(455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory...
-
604.9.1 Location
(455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory...
-
11B-604.9.1 Location
(457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory...
-
11B-604.9.1 Location
(457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory...
-
Doors: ADA Standard Section 604.8.1.2
Section 604.8.1.2 covers the current ADA Standards for wheelchair accessible compartment doors.
-
11B-604.9.1 Location
(457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory...
- Eclipse Partitions Stall Breakdown Animation
- Hadrian Powder Coated Headrail Braced Toilet Partition Installation
-
36 Inch Wide Stalls
36 Inch Wide Stalls Where 6 or more stalls are provided (including accessible stalls) in a toilet room or bathroom, at least one must meet requirements for ambulatory access as required...
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
11B-604.8.2.3 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
-
11B-604.8.2.3 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...