Elevators shall comply with 407 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1). They shall be passenger elevators as classified by ASME...
Search Results "ASTM: American Society for Testing and Materials"
Commonly Searched Documents
-
407.1 General
-
4.10.6* Door Protective and Reopening Device
Elevator doors shall open and close automatically. They shall be provided with a reopening device that will stop and reopen a car door and hoistway door automatically if the door...
-
A4.10.6 Door Protective and Reopening Device
The required door reopening device would hold the door open for 20 seconds if the doorway remains obstructed. After 20 seconds, the door may begin to close. However, if designed in...
-
4.10.1 General
Accessible elevators shall be on an accessible route and shall comply with 4.10 and with the ASME A17.1‒1990, Safety Code for Elevators and Escalators. Freight elevators shall not be...
-
A4.10.6 DOOR PROTECTIVE AND REOPENING DEVICE
The required door reopening device would hold the door open for 20 seconds if the doorway remains unobstructed. After 20 seconds, the door may begin to close. However, if designed in...
-
11B-411.1 General
Destination-oriented elevators shall comply with Section 11B-411 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be...
-
11B-810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 and shall have a clear width of 32 inches (813 mm) minimum. Exception: Existing...
-
11B-810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 and shall have a clear width of 32 inches (813 mm) minimum. Exception: Existing...
-
11B-411.1 General
Destination-oriented elevators shall comply with Section 11B-411 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be...
-
§ 36.209(c) Drug testing
(c) Drug testing....
-
§ 35.131(c) Drug testing
(c) Drug testing....
-
APPROVED TESTING AGENCY
APPROVED TESTING AGENCY. ...
-
APPROVED TESTING AGENCY
[HCD 1, HCD 2 & DSA-AC] Any agency, which is determined by the enforcing agency, except as otherwise provided by law, to have adequate personnel and expertise to carry out the testing...
-
Sec.36.309(a) General
(a) General. Any private entity that offers examinations or courses related to applications, licensing, certification, or credentialing for secondary or postsecondary education,...
-
§ 36.309(a) General
(a) General. Any private entity that offers examinations or courses related to applications, licensing, certification, or credentialing for secondary or postsecondary education,...
-
§100.141 Self-test
Self-test means any program, practice or study a lender voluntarily conducts or authorizes which is designed and used specifically to determine the extent or effectiveness of compliance...
-
APPROVED TESTING AGENCY
amp; OSHPD 1, 1R, 2, 4 & 5] Any agency, which is determined by the enforcing agency, except as otherwise provided by law, to have adequate personnel and expertise to carry out the testing...
-
E102.2 ANSI/HFES (Section-by-Section Analysis)
E102.2 ANSI/HFES (Section-by-Section Analysis) ANSI/HFES 200.2, Human Factors Engineering of Software User Interfaces — Part 2: Accessibility (2008), would be incorporated by...
- ASME
-
1630.16(c)(1)
For purposes of this part, a test to determine the illegal use of drugs is not considered a medical examination....
-
§1630.16(c)(1) General policy
For purposes of this part, a test to determine the illegal use of drugs is not considered a medical examination....
-
Section 36.309 Examinations and Courses (Section-By-Section Analysis and Response to Comments)
Paragraph (a) restates section 309 of the Americans with Disabilities Act....
-
Measuring Surface Firmness and Stability
The rotational penetrometer (RP) is a precision surface-indenter measuring tool for evaluating the firmness and stability of ground and floor surfaces (figure 1). To measure...
-
408.1 General
Limited-use/limited-application elevators shall comply with 408 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1). They shall be passenger...