"functional spaces'' as "[t]he rooms and spaces in a building or facility that house the major activities for which the building or facility is intended.''...
Search Results "Lavatory Clear Floor Space"
-
Section 36.403 Alterations: Path of Travel (Section-By-Section Analysis and Response to Comments)
-
H1
ADA Standards § 4.30.6] Yes No If No, install a sign with raised characters and Braille on the wall adjacent to the latch side of the door and centered 60 inches above the floor...
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
407.2.2.1 Visible and Audible Signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. EXCEPTIONS: 1....
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-603.5 Accessories
All operable parts, including coin slots, shall be 40 inches (1016 mm) maximum above the finish floor....
-
407.12.3.1 Unobstructed Forward Reach (Section-by-Section Analysis)
Analysis) This section proposes that, where an unobstructed forward reach is provided, the operable part must be located 48 inches high maximum and 15 inches high minimum above the floor...
-
407.12.2.2 Obstructed Side Reach (Section-by-Section Analysis)
located more than 10 inches, but not more than 24 inches, behind the vertical reference plane, the height of the operable part must be 46 inches maximum and 15 inches minimum above the floor...
-
4.10.6* Door Protective and Reopening Device
device shall be capable of completing these operations without requiring contact for an obstruction passing through the opening at heights of 5 in and 29 in (125 mm and 735 mm) above finish floor...
-
4.10.3 Hall Call Buttons
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
4.13.9* Door Hardware
Hardware required for accessible door passage shall be mounted no higher than 48 in (1220 mm) above finished floor....
-
4.10.3 HALL CALL BUTTONS
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
Safety Considerations for Site Selection
When possible, request meeting rooms on the ground floor with direct accessible paths to the outside....
-
Slope [4.3.7]
Requirements in 4.3, while based on the expectation of level floors, apply equally to exterior sites....
-
4.10.6* DOOR PROTECTIVE AND REOPENING DEVICE
device shall be capable of completing these operations without requiring contact for an obstruction passing through the opening at heights of 5 in and 29 in (125 mm and 735 mm) from the floor...
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
- Access-Able Designs Adult Dressing Bench D-101-42
-
What employment practices are covered by the ADA?
A retail store that generally rotated all sales associates between the sales floor (where they could earn commissions) and the stock room (where they processed merchandise) except for the...
-
III-7.5170 Telephones
telephones and need "text telephones" (referred to in the Department's rule as telecommunication devices for the deaf (TDD's)): 1) One accessible public phone must be provided for each floor...
-
Protruding Objects
project more than 12 inches into walks, halls, corridors, passageways, aisles, or any other area where a person walks at heights between 27 inches and 80 inches above the ground or finished floor...
-
BHMA
Builders Hardware Manufacturers’ Association 355 Lexington Avenue, 15th Floor New York, NY 10017-6603 A 156.10-2011: Power Operated Pedestrian Doors 1010.1.4.2, 11B-404.2.9,...
-
11B-608.5.3 Alternate roll-in type shower compartments
The controls, faucets, and shower spray units shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor....