This space efficient, single stack unit enables individuals with varied arm and hand strength to perform at a comfortable level with little or no assistance....
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
- Apex Challenge Circuit CH7000
-
Building Support for S. 933
On each anniversary of his injury, April 14, he gave a speech about disability on the Senate floor....
- Society for the Blind
- Neurofibromatosis Network
-
11B-405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
-
Broad Coverage
The ADA Amendments Act cleared up the confusion by stating that bodily functions are indeed major life activities....
-
12. Grievance procedure
A sentence was also added to make clear that grievance procedures are not required to be made available to unsuccessful applicants for employment or to applicants for admission to colleges...
-
2. How may an employer identify individuals who may require assistance?
An employer also may periodically survey all of its current employees to determine whether they will require assistance in an emergency, as long as the employer makes it clear that self-identification...
-
Contractual arrangements with private entities. (Section-by-Section Analysis)
For that reason, the proposed § 35.152(a) makes it clear that this section's requirements will apply to prisons operated by public entities directly or through contractual or other relationships...
-
Guidelines for Requirement 3
(2) For doors within individual dwelling units, the Department has retained, in the final Guidelines, the design specification that a door with a clear opening of at least 32 inches...
-
Elevated Dune Crossings
The clear width of elevated dune crossings may be narrower than the rest of the beach access route, but must be at least 48 inches (1,220 millimeters)....
-
11B-405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
-
11B-405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
-
11B-217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
I don’t want to discriminate against patients with disabilities, but I don’t want my staff to injure their backs by lifting people who use wheelchairs onto exam tables. If my nurse has a bad back, then she doesn’t have to help lift a patient, does she?
The medical provider can protect his or her staff from injury by providing accessible equipment, such as an adjustable exam table and/or a ceiling or floor based patient lift, and training...
-
3. What types of complaints does the ADA Mediation Program resolve?
refuses to serve a person with a disability because he or she uses a service animal; and, Program accessibility: alleging that a city hall's public meetings are held on the second floor...
-
M302.2.1 Adjustability (Section-by-Section Analysis)
position of 25 inches; (3) at least four additional transfer positions located between the low and high transfer positions and separated by one inch minimum increments; (4) measured from the floor...
-
Measuring Surface Firmness and Stability
The rotational penetrometer (RP) is a precision surface-indenter measuring tool for evaluating the firmness and stability of ground and floor surfaces (figure 1). ...
-
11B-411.2.2.2 Verbal identification
volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the elevator entrance and at 48 inches (1219 mm) above the floor...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
abilities of power chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
abilities of manual chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor...
-
4.10.4 HALL LANTERNS
Visible signals shall have the following features: (1) Hall lantern fixtures shall be mounted so that their centerline is at least 72 in (1830 mm) above the lobby floor....
-
11B-411.2.2.2 Verbal identification
volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the elevator entrance and at 48 inches (1219 mm) above the floor...
-
Stairs
At the top, the extension shall be parallel with the floor or ground surface....