Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
Search Results "Water Closet Clear Floor Space"
-
11B-407.4.10.1 Location
-
605.2 Height and Depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
804.3.2 Height
The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground....
-
K. Ambulatory Stall
If there are more than 5 stalls in any restroom, is there one stall in addition to the large accessible stall, that is 36" wide, has 2 parallel grab bars at 33"-36" off the floor and has...
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
Audible Tones/Bells or Verbal Annunciators
...are all of the elevators equipped with audible tones/bells or verbal annunciators that designate the passage of floors?...
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
4.10.2 Automatic Operation
Each car shall be equipped with a self-leveling feature that will automatically bring the car to floor landings within a tolerance of 1/2 in (13 mm) under rated loading to zero loading conditions...
-
4.10.2 AUTOMATIC OPERATION
Each car shall be equipped with a self-leveling feature that will automatically bring the car to floor landings within a tolerance of 1/2 in (13 mm) under rated loading to zero loading conditions...
-
Knowing audio description is present in the exhibition
A difference in floor texture could be used to cue visitors with vision loss where the panels with description buttons are located....
-
4.27.3* HEIGHT
Except where the use of special equipment dictates otherwise, electrical and communications system receptacles on walls shall be mounted no less than 15 in (380 mm) above the floor....
-
§100.201a(b)(1) ICC/ANSI A117.1-2003
., 6th Floor, Washington, DC 20001-2070, telephone number 1-888-422-7233, http://www.iccsafe.org/e/category.html....
-
§100.201a(b)(2) ICC/ANSI A117.1-1998
., 6th Floor, Washington, DC 20001-2070, telephone number 1-888-422-7233, http://www.iccsafe.org/e/category.html....
-
§100.201a(b)(3) CABO/ANSI A117.1-1992
., 6th Floor, Washington, DC 20001-2070, telephone number 1-888-422-7233, http://www.iccsafe.org/e/category.html....
-
§ 38.83(c)(3) Ramp threshold
The transition from roadway or station platform and the transition from vehicle floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
§ 38.125(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1⁄4 inch....
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
11B.707.7.1.2 Angle-mounted display screen
away from the viewer 30 degrees to less than 60 degrees from vertical, the center line of the display screen and other display devices shall be no more than 44 inches (1118 mm) above the floor...
-
1.9.1.2 Application
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
- Gerber Electronic Toilet Flush Valve 44-912
-
1013.2 Where required
located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor...
-
Suggestion by Eldon Tipping
Suggestion by Eldon Tipping As published in Concrete Construction magazine, September 1998, Eldon Tipping made suggestions for a specification for sloped random - traffic floors such as...
-
Destination-Oriented Elevators
With destination-oriented elevators, passengers indicate the floor destination when calling an elevator, usually through a keypad....