Accessible means of entry shall be swimming pool lifts complying with Section 11B-1009.2; sloped entries complying with Section 11B-1009.3; transfer walls complying with Section 11B-1009.4...
Search Results "Transfer Shower"
Commonly Searched Documents
-
11B-242.2 Swimming pools
-
Bathtubs (ADAAG 4.20)
Bathtubs (ADAAG 4.20) ADA Accessibility Guidelines for bathtubs are predicated on the use of a conventional residential bathtub by individuals who independently transfer from a wheelchair...
-
Width and Length
Width and Length Transfer walls must be a minimum of 12 inches wide to a maximum of 16 inches wide....
-
Guest Room Doors and Doorways: ADA Standard Section 224.1.2
Section 224.1.2 covers scoping requirements in the current ADA Standards for transient lodging guest room doors and doorways.
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302 Description: This minimum distance ensures that the transfer support is within reach of the transfer...
-
Highest and Lowest Heights Obtained
These data represent the ability of the participants in the study to complete a transfer....
-
§ 36.302(f)(6) Ticket transfer
(6) Ticket transfer....
-
4.26.1* GENERAL
All handrails, grab bars, and tub and shower seats required to be accessible by 4.1, 4.8, or 4.9 shall comply with 4.26....
-
Space Needs
Table 11 shows that for a given width of 40 inches (centered in front of the transfer station) that 25% of the subjects were able to perform a transfer to the platform in Protocol A (no...
-
5.3.2 Transfer Sides Recommendations for M301
5.3.2 Transfer Sides Recommendations for M301 Description: The transfer side provision requires the transfer surface to be located to provide options to transfer onto the short side and...
- Inpro Corporation Clickeze® ADA Shower Curtain
-
5.4.1 Transfer Support Location for M301 and M302
5.4.1 Transfer Support Location for M301 and M302 Description: Transfer supports assist individuals while making transfers on to the transfer area....
-
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface where...
-
4.26.1* General
All handrails, grab bars, and tub and shower seats required to be accessible by 4.1, 4.8, 4.9, 4.16, 4.17, 4.20 or 4.21 shall comply with 4.26....
-
Height
The Access Board is considering whether 6 inches minimum and 19 inches maximum above the transfer surface would be an appropriate height for transfer supports on diagnostic equipment used...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum....
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum....
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
- Symmons Duro® Tub Shower System 3S603-H321-V
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum....
-
Transfer Surface Height (M301.2.1 and M302.2.1)
M301.2.1 and M302.2.1 would require the height of the transfer surface during patient transfer to be 17 inches minimum and 19 inches maximum measured from the floor to the top of the transfer...