Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
Search Results "Portable Ramp"
-
405.7.4 Change in Direction
-
Section 406.8
maintain the status quo with respect to detectable warnings in pedestrian facilities, the Department is adding a provision (not found in the current version of the new ADAAG) requiring curb ramps...
-
Polling place violations that can be remediated with temporary measures
Building Entrance: The area in front of the exterior entrance on the ramp contains no level landing (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4)....
-
d-i
[ADA Standards § 4.8.2] Yes No Note: For existing ramps, the slope may be 1:10 for a 6-inch rise and 1:8 for a 3-inch rise in special circumstances]....
-
4a.
[ADA Stds 4.8.2] Yes _____ No _____ Note: For existing ramps, the slope may be 1:10 for a 6 inch rise and 1:8 for a 3 inch rise in special circumstances, see ADA Standards 4.1.6(3)...
- How to Determine the Total Rise of a Ramp Run
-
9.b [§ 4.7.5]
9.b [§ 4.7.5] If the sidewalk at the top of the ramp (“x”) is less than 48 inches wide and the curb ramp you are surveying has flared sides, answer this question....
-
Height: ADA Standard Section 505.4
Section 505.4 covers the current ADA Standards for the height of the top of the gripping surface of handrails.
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
Clearances: ADA Standard Section 1003.3
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with 1003.3. Advisory 1003.3 Clearances....
-
Inaccessible Town Program
While the fundraising is done, alterations planned, and the work completed, the town provides temporary portable toilet facilities that are accessible....
-
f-i
[ADA Standards § 4.8.2] Yes No Note: For existing ramps, the slope may be 1:10 for a 6-inch rise and 1:8 for a 3-inch rise in special circumstances (see ADA Standards § 4.1.6...
-
5. Curb ramps
Curb ramps 4.7 Accessible routes crossing curbs....
-
11B-1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with Section 11B-1003.3. Advisory 11B-1003.3 Clearances....
-
11B-1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with Section 11B-1003.3. Advisory 11B-1003.3 Clearances....
-
Using Patient Lifts
Using Patient Lifts Medical providers may need a lift in order to transfer some patients safely onto an exam table. Patient lifts may move along the floor or be mounted on an...
-
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers. The base of the equipment must provide a clearance of 39 inches wide minimum.
-
Surfaces: ADA Standard Section 505.8
Section 505.8 covers the current ADA Standards for handrail gripping surfaces and also any adjacent surfaces to them.
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges.
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges.
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
§ 38.125(c)(3) Ramp threshold
(3) Ramp threshold....
-
§ 38.95(c)(3) Ramp threshold
(3) Ramp threshold....