Exception: Where multi-story residential dwelling units are one of the types of residential dwelling units provided, one-story residential dwelling units shall be permitted as a substitute...
Search Results "Permit"
-
11B-233.3.5 Dispersion
-
11B-224.8.2 More than 50-bed facilities
Transfer-type showers are not permitted in lieu of a roll-in shower with a seat, and the exceptions in sections 608.3 and 608.4 for residential dwelling units are not permitted. ...
-
11B-608.6 Shower spray unit and water
Exception: Where subject to excessive vandalism, two fixed shower heads shall be permitted instead of a hand-held spray unit in facilities that are not medical care facilities, long-term...
-
11B-224.8.2 More than 50-bed facilities
Transfer-type showers are not permitted in lieu of a roll-in shower with a seat, and the exceptions in sections 608.3 and 608.4 for residential dwelling units are not permitted. ...
-
11B-207.1 General
Exceptions: Where means of egress are permitted by local building or life safety codes to share a common path of egress travel, accessible means of egress shall be permitted to share...
-
11B-608.6 Shower spray unit and water
Exception: Where subject to excessive vandalism, two fixed shower heads shall be permitted instead of a hand-held spray unit in facilities that are not medical care facilities, long-term...
-
11B-104.1.1 Construction and manufacturing tolerances
bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate tolerance and therefore no tolerance outside of the range at either end point is permitted...
-
11B-104.1.1 Construction and manufacturing tolerances
bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate tolerance and therefore no tolerance outside of the range at either end point is permitted...
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
804.6.1 Clear Floor or Ground Space
Clear floor or ground spaces shall be permitted to overlap....
-
1630.16(f)(4)
(4) The activities described in paragraphs (f)(1),(2), and (3) of this section are permitted unless these activities are being used as a subterfuge to evade the purposes of this part....
-
11B-206.7.3 Incidental spaces
Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
-
11. Q: If an applicant tests positive for illegal drug use, can I ask whether he or she is using any prescription medications under a doctor's care that may have caused a positive result?
Inquiries into the use of prescription drugs are permitted in response to a positive drug test, even though the answers may disclose information about a disability....
-
407.3.6 Width
EXCEPTION: In existing elevators, a power-operated car door complying with 404.2.3 shall be permitted....
-
F206.7.3 Incidental Spaces
Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
804.6.1 Clear Floor or Ground Space
Clear floor or ground spaces shall be permitted to overlap....
-
(4) the City's Guidelines for Paving and Accessibility Compliance
(4) the City's Guidelines for Paving and Accessibility Compliance which permits the City to install curb ramps up to two years after re-paving;...
-
206.7.3 Incidental Spaces
Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
-
T102.1 Calculation of Percentages
Where the determination of the required size or dimension of an element involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
802.3.2 Type
Companion seats shall be permitted to be movable....
-
R102 Equivalent Facilitation
The use of alternative designs, products, or technologies that result in substantially equivalent or greater accessibility and usability than the requirements in this document is permitted...
-
4.1.6(3)(d)(i)
(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop....
-
§100.301(b)
(b) Nothing in this part limits the applicability of any reasonable local, State, or Federal restrictions regarding the maximum number of occupants permitted to occupy a dwelling....