A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided. Knee and toe space complying with Section 11B-306...
Search Results "Latch Side Clearance"
-
11B-904.4.2 Forward approach
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair space....
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
Can clear floor/ground space or turning space overlap other space requirements?
Yes, clear floor or ground spaces and turning space can overlap other required clearances, including other clear floor spaces, door maneuvering clearances, and fixture clearances....
-
11B-406.5.10 Diagonal curb ramps
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
-
11B-406.5.10 Diagonal curb ramps
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
- Figure 307.4 Vertical Clearance – Drawing from the U.S. Access Board
- 307.4 Door Opening Vertical Clearance
-
C. Doors
_____________________ ...with the exception of guestrooms not designated as accessible, does at least one door to each accessible space have at least 18" of clear floor space on the latch...
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the...
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the...
-
Clear Floor Space [§309.2]
Clear Floor Space [§309.2] Clear floor space can be oriented for a side approach instead of a forward approach at most operable parts....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position; M302 Diagnostic Equipment Used by Patients in Seated Position
M301 provides technical criteria for diagnostic equipment used by patients in a supine, prone, or sidelying position, and M302 provides technical criteria for diagnostic equipment used by...
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
Door and Gate Surfaces [§404.2.10]
Door and Gate Surfaces [§404.2.10] The bottom surface of doors and gates on the push side must be smooth to a height of at least 10”....
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
-
6.3(4)
(4) Each four-bed room shall have a minimum clear floor space of 48 in (1220 mm) from the foot of the bed to the foot of the opposing bed; 36 in (915 mm) between the side of the bed and...
-
5.8.2.1 Height of Breast Platform at Time of Measurement
The NPRM proposed measuring the knee clearance under the breast platform at 27 inches above the ground....
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....