Where spectators are provided lines of sight over the shoulders and between the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces...
Search Results "End of Row Compartment"
Commonly Searched Documents
-
802.2.1.2 Lines of Sight between Heads
-
802.2.2.2 Lines of Sight between Heads
Where standing spectators are provided lines of sight over the shoulders and between the heads of spectators standing in the first row in front of their seats, spectators seated in wheelchair...
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
802.2.2.2 Lines of Sight between Heads
Where standing spectators are provided lines of sight over the shoulders and between the heads of spectators standing in the first row in front of their seats, spectators seated in wheelchair...
-
11B-502.6.3 Location
Signs shall be permanently posted either immediately adjacent to the parking space or within the projected parking space width at the head end of the parking space....
-
11B-809.10.5.2 Reinforcement for grab bars
At the control end wall and head end wall, between 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor, extending 28 inches (711 mm) minimum from the front edge...
-
Wheelchair Spaces
and from other wheelchair spaces in the same row....
- Hussey Seating Company In-Fill Decks
-
3.6 Youngstown Tinseltown 7, 7401 Market Street, Boardman, Ohio
3.6 Youngstown Tinseltown 7 7401 Market Street, Boardman, Ohio - In Auditorium 3, the four (4) wheelchair spaces shall be relocated one row farther back in the auditorium from their...
-
§ 1194.22(g)
(g) Row and column headers shall be identified for data tables....
-
Back Wall: ADA Standard Section 607.4.1.1
Section 607.4.1.1 covers the current ADA Standards for back wall grab bars in bathtubs with permanent seats.
-
1. Movable aisle armrests
Such armrests need not be provided on emergency exit row seats or on seats on which movable aisle armrests are not feasible....
-
§382.41(a)
., by row and seat number);...
-
221.9 Stadium Style Movie Theaters
vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing angles for all seats as ranked from the seats in the first row...
-
11B-607.4.1.1 Back wall
Each grab bar shall be installed 15 inches (381 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
11B-236.1 General
Similarly, there are many types of cardiovascular exercise machines, such as stationary bicycles, rowing machines, stair climbers, and treadmills....
- Equalizer 6000 Series Exercise Machine
-
Bobrick Partition-Mounted Multi-Roll Toilet Tissue Dispenser (Serves 2 Compartments) B-386
Requires the Premium User plan or above. (Login or upgrade your account!)
- Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
- Figure 608.5.1 Transfer Type Shower Compartment Control Location – Drawing from the U.S. Access Board
-
Transition Plate
A sloping pedestrian walking surface located at the end(s) of a gangway....
-
Back Wall: ADA Standard Section 607.4.2.1
Section 607.4.2.1 covers the current ADA Standards for back wall grab bars in bathtubs without permanent seats.
-
11B-607.4.2.1 Back wall
Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
Wheelchair seating locations must provide lines of sight comparable to those provided to other spectators.
line of sight, as illustrated in the figure below, allows a person using a wheelchair to see the playing surface between the heads and over the shoulders of the persons standing in the row...