Where provided, protective surfaces over signs shall have a non-glare finish....
Search Results "Edge Protection"
Commonly Searched Documents
-
T702.8 Contrast
-
Multi-Level Parking Garage Not Serving a Particular Facility
Accessible spaces, including van spaces, must be located so that they provide the same level of protection and security as other spaces in the garage....
-
Swimming pools, wading pools, saunas, and steam rooms. (Section-by-Section Analysis)
Such an exemption for saunas and steam rooms that seat only two people is unnecessary because the readily achievable standard provides sufficient protection against barrier removal that...
-
M15
Are all built-in dispensers, receptacles, or equipment mounted so the front does not extend more than 4 inches from the wall if the bottom edge is between 27 inches and 80 inches above the...
-
H14
Are all built-in dispensers, receptacles, or equipment mounted so the front does not extend more than 4 inches from the wall if the bottom edge is between 27 inches and 80 inches above the...
-
11B-235.2 Boat slips
Where the number of boat slips is not identified, each 40 feet (12192 mm) of boat slip edge provided along the perimeter of the pier shall be counted as one boat slip for the purpose of...
-
R402 Protruding Objects (Section-by-Section Analysis)
R402 Protruding Objects (Section-by-Section Analysis) Objects with leading edges between 685 millimeters (2.25 feet) and 2 meters (6.7 feet) above the finish surface must not protrude...
-
235.2 Boat Slips
Where the number of boat slips is not identified, each 40 feet (12 m) of boat slip edge provided along the perimeter of the pier shall be counted as one boat slip for the purpose of this...
-
11B-235.2 Boat slips
Where the number of boat slips is not identified, each 40 feet (12192 mm) of boat slip edge provided along the perimeter of the pier shall be counted as one boat slip for the purpose of...
-
11B-235.2 Boat slips
Where the number of boat slips is not identified, each 40 feet (12192 mm) of boat slip edge provided along the perimeter of the pier shall be counted as one boat slip for the purpose of...
-
12209(b)(3)(B)
--The Architect of the Capitol shall establish remedies and procedures to be utilized with respect to the rights and protections provided pursuant to subparagraph (A)....
-
12209(a)(2)(B) Remedies
--The Architect of the Capitol shall establish remedies and procedures to be utilized with respect to the rights and protections provided pursuant to subparagraph (A)....
-
606.5 Exposed Pipes and Surfaces
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact....
-
§35.190(b)(5)
Department of Interior: all programs, services, and regulatory activities relating to lands and natural resources, including parks and recreation, water and waste management, environmental protection...
-
§ 35.190(b)(5) Department of Interior
Department of Interior: All programs, services, and regulatory activities relating to lands and natural resources, including parks and recreation, water and waste management, environmental protection...
-
R402.4 Reduced Vertical Clearance
The leading edge of the guardrail or barrier shall be located 685 mm (2.25 ft) maximum above the finish surface....
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
The horizontal distance from the transfer surface should be no more than 3 inches from the edge of the patient support surface....
-
Stairways [§504]
Recommendation: Providing visual contrast (light-on-dark or dark-on-light) on the top and bottom steps that is approximately 2 inches wide and located either on nosings or at the leading edges...
-
11B-306.3.3 Minimum required depth
686 mm) high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge...
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
407.12.3.2.2 Knee and Toe Space
be permitted to provide a clear height of 9 inches (230 mm) minimum above the floor and a clear depth of 6 inches (150 mm) maximum from the vertical reference plane toward the leading edge...
-
1.1.6 Flatness of walk cross slope
Measure along two paths, each with the end of the digital inclinometer 1 ft (300 mm) from the edge of the path and placed toward the middle of the path. See Fig. 2....
-
11B-306.3.3 Minimum required depth
686 mm) high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge...
-
11B-306.3.3 Minimum required depth
686 mm) high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge...