Search Results "Door Opening Force"
Commonly Searched Documents
- 307.4 Door Opening Vertical Clearance
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]...
-
4.1.3(7)(a)
(a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
-
Exit Doors: ADA Standard Section 216.4.1
Section 216.4.1 covers scoping requirements in the current ADA Standards for signs at exit doors.
-
Maneuvering Clearances [§404.2.4]
Maneuvering Clearances [§404.2.4] Required maneuvering clearances provide space for opening and proceeding through doors, doorways, and gates using wheelchairs and other mobility aids...
-
(1)(e)
(e) Doorways on the end of the enclosure, opposite the water closet, should have a minimum clear opening width of 32 inches (815 mm)....
-
D2
Does at least one door or one side of a double leaf-door provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
F206.5.1 Entrances
Each entrance to a building or facility required to comply with F206.4 shall have at least one door, doorway, or gate complying with 404....
-
206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
F206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
-
206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
-
Inventory Control Devices
Inventory Control Devices It is important that inventory control or security devices not obstruct required maneuvering clearances at doors....
-
206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
4.10.6* Door Protective and Reopening Device
Elevator doors shall open and close automatically....
-
Re: How to Use the Pressure Gauge Tool
WARNING - We have stopped carrying the HMC International spring-type door pressure gauges shown in the video because the last two large shipments we received were all exactly one pound off...
-
§ 38.159(b)(7) Platform gaps
Any openings between the platform surface and the raised barriers shall not exceed 5/8 inch (16 mm) in width....
-
206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
-
F206.5.3 Transient Lodging Facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2...
-
206.5.3 Transient Lodging Facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2...
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....