These dimensions are: (A) occupied width, the horizontal distance between the side-most (lateral-most) points of the wheelchair or occupant on the right and left side; (B) occupied length...
Search Results "Change in Occupancy"
Commonly Searched Documents
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
These dimensions are: (A) occupied width, the horizontal distance between the side-most (lateral-most) points of the wheelchair or occupant on the right and left side; (B) occupied length...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Power Chair
These dimensions are: (A) occupied width, the horizontal distance between the side-most (lateral-most) points of the wheelchair or occupant on the right and left side; (B) occupied length...
-
OCCUPIABLE SPACE
A room or enclosed space designed for human occupancy in which individuals congregate for amusement, educational or similar purposes or in which occupants are engaged at labor, and which...
-
OCCUPIABLE SPACE
A room or enclosed space designed for human occupancy in which individuals congregate for amusement, educational or similar purposes or in which occupants are engaged at labor, and which...
-
Principal features of the Option One guidelines that were not changed in the final Guidelines include the following:
[See subsections ...]
-
1132A.8.1 Lever-type hardware
or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group R and U Occupancies...
-
1132A.8.1 Lever-type hardware
or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group R and U Occupancies...
-
Notification Devices: ADA Standard Section 806.3.2
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
11B-802.1.5 Overlap
The term "circulation paths" used in Section 11B-802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....
-
OCCUPIABLE SPACE
A room or enclosed space designed for human occupancy in which individuals congregate for amusement, educational or similar purposes or in which occupants are engaged at labor, and which...
-
[A] 101.4.4 Property maintenance
apply to existing structures and premises; equipment and facilities; light, ventilation, space heating, sanitation, life and fire safety hazards; responsibilities of owners, operators and occupants...
-
101.4.4 Property maintenance
apply to existing structures and premises; equipment and facilities; light, ventilation, space heating, sanitation, life and fire safety hazards; responsibilities of owners, operators and occupants...
-
Issue 11: What environmental and perceptual data on natural/daylighting are available from buildings with low vision occupants?
Question by [Participant]: Jim, can I just ask one quick question? So did you actually survey persons with low vision to come up with this information? Response by Jim Woods: We...
-
11B-805.2 Patient bedrooms and resident sleeping rooms
Note According to the Office of Statewide Health Planning and Development (OSHPD), "resident sleeping rooms," not defined in CBC Chapter 2, refers to the bedrooms of long-term care occupants...
-
[A] 101.4.4 Property maintenance
apply to existing structures and premises; equipment and facilities; light, ventilation, space heating, sanitation, life and fire safety hazards; responsibilities of owners, operators and occupants...
-
General: ADA Standard Section 223.1
Section 223.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for medical care and long-term care facilities.
-
Technical Memorandum TM 2013-19 Private Toilet and Bathing Rooms
TM 2013-19 Private Toilet and Bathing Rooms Effective Date: October 3, 2013 2012 TAS Reference: 213.2 and 213.3 A toilet or bathing room for a single occupant accessed only...
-
4.1.4(2) MILITARY EXCLUSIONS
The following facilities need not be designed to be accessible, but accessibility is recommended since the intended use of the facility may change with time....
-
1132A.8.1 Lever-type hardware
or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group R and U Occupancies...
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
907.2.5 Group H
A manual fire alarm system shall be installed in Group H-5 occupancies and in occupancies used for the manufacture of organic coatings....
-
§100.307(b)
(b) A facility or community shall, within 180 days of the effective date of this rule, develop procedures for routinely determining the occupancy of each unit, including the identification...
-
68.10(6) Completion of Construction
(6) Completion of Construction--The date when a construction project results in occupancy or the issuance of a certificate of occupancy....