Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
Search Results "Technical Requirement"
Commonly Searched Documents
-
11B-404.2.8.1 Door closers and gate closers
-
Multi-Level Parking Garage Not Serving a Particular Facility
Locating accessible spaces required for a garage on the exterior is not usually acceptable....
-
Passing Space [§403.5.3]
Passing Space [§403.5.3] Passing space is required every 200 feet and must be provided as a 60” by 60” minimum space or as T-shaped space where each stem is at least 48” long....
-
§ 38.95(c)(6)(ii) Exception
Ramps or bridge plates which are attached to, and deployed from, station platforms are permitted in lieu of car devices provided they meet the displacement requirements of paragraph (c)(...
-
11B-1008.3.2 Transfer steps
Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes....
-
§ 37.145(c)
(c) Forward the required certification with comments on each plan to FTA....
-
§ 38.83(c)(6)(ii) Exception
Ramps or bridge plates which are attached to, and deployed from, station platforms are permitted in lieu of vehicle devices provided they meet the displacement requirements of paragraph...
-
Section 37.79 Purchase or Lease of New Rail Vehicles by Public Entities Operating Rapid or Light Rail Systems
Section 37.79 Purchase or Lease of New Rail Vehicles by Public Entities Operating Rapid or Light Rail Systems This section echoes the requirement of §37.71—all new rail cars must be accessible...
-
§ 38.125(c)(6)(ii) Exception
Ramps or bridge plates which are attached to, and deployed from, station platforms are permitted in lieu of car devices provided they meet the displacement requirements of paragraph (c)(...
-
11B-208.2.4 Van parking spaces
For every six or fraction of six parking spaces required by Section 11B-208.2 to comply with Section 11B-502, at least one shall be a van parking space complying with Section 11B-502. ...
-
Section 406.8
406.8 To maintain the status quo with respect to detectable warnings in pedestrian facilities, the Department is adding a provision (not found in the current version of the new ADAAG) requiring...
-
16) Elevator hoistway floor designations and car controls
UFAS: Must have raised characters; no requirement for Braille (§§4.10.5; 4.10.12)....
-
2) Valet parking
UFAS: No requirements for valet parking....
-
11B-1008.3.2 Transfer steps
Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-1009.3.1 Sloped entries
Exception: Where sloped entries are provided, the surfaces shall not be required to be slip resistant....
-
11B-208.2.4 Van parking spaces
For every six or fraction of six parking spaces required by Section 11B-208.2 to comply with Section 11B-502, at least one shall be a van parking space complying with Section 11B-502....
-
4. Assess During the Planning, Installation and Maintenance Phases
playground surface is installed, an on-site inspection of the surface system should be conducted along the accessible routes, at the clear ground spaces for entry/egress of equipment and required...
- Willoughby Industries WAF-3300 AquaFount® Three Station Solid Surface Washfountain
- Norton 5600 Series Low Energy Operator
- Caroma® USA Caravelle Smart 270 One Piece Toilet
- Door King Inc. 9000 Commercial and Industrial Slide Gate Operator
- TownSteel CE/CEC Series, Grade 1, Heavy Duty Cylindrical Locks