Negotiability and Flexibility Commercial leases are generally subject to a great deal of negotiation between owners and landlords, since businesses often need specific features in their spaces...
Search Results "Lavatory Clear Floor Space"
Commonly Searched Documents
-
2. a. i. Negotiability and Flexibility
-
4.32.3 KNEE CLEARANCES
If seating for people in wheelchairs is provided at tables, counters, and work surfaces, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided...
-
11B-406.5.6 Grade breaks
Grade breaks shall not be permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks shall be flush....
-
11B-406.5.6 Grade breaks
Grade breaks shall not be permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks shall be flush....
-
Application Based on Building or Facility Use: ADA Standard Section 201.2
Section 201.2 covers the application of the most current requirements based on the building or facility use.
-
907.5.2.3.2 Groups R-1 and R-2.1
Habitable spaces in dwelling units and sleeping units in Group R-1 and R-2.1 occupancies in accordance with Table 907.5.2.3.2 shall be provided with visible alarm notification....
-
ALIGNMENT OF 19-INCH RECOMMENDATION WITH ACCESS BOARD PROPOSED RULEMAKING
proposed rule, the Access Board proposed that the “height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor...
-
Kohler Branham™ Urinal Model K-4920-R-0
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-610.3 Shower compartment seats
The top of the seat shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
What other surface considerations affect wheelchair travel?
In addition to slip resistance requirements, wheelchair users are affected by the rolling resistance of the surface of the floor and--on exterior surfaces--by cross slope....
-
(1) Site impracticality
Every dwelling unit on a floor served by an elevator must be on an accessible route, and must be made accessible in accordance with the Act's requirements for covered dwelling units....
-
11B-703.5.5 Character height
Exception: Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.5....
-
11B-703.5.5 Character height
Exception: Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.5....
-
11B-610.3 Shower compartment seats
The top of the seat shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-608.6 Shower spray unit and water
One shower head shall be located at a height of 48 inches (1219 mm) maximum above the shower finish floor....
-
11B-703.5.5 Character height
Exception: Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.5....
-
11B-608.6 Shower spray unit and water
One shower head shall be located at a height of 48 inches (1219 mm) maximum above the shower finish floor....
-
Access Aisle
Section 502.3 of the 2010 Standards requires that an accessible route adjoin each access aisle serving accessible parking spaces....
-
Areas of Sport Activities
The "area of sport activity" is "that portion of a room or space where the play or practice of a sport occurs." For example, football fields are defined by boundary lines....
-
Toilet Rooms North (Celebrity Spies)–Women [sic]
The toilet seat is 20" above the finished floor and exceeds the allowable range of 17" to 19". See Standards § 4.16.3....
-
4. Who is allowed to have information about employees needing assistance in an emergency?
exception would allow an employer to share information about the type of assistance an individual needs in the event of an evacuation with medical professionals, emergency coordinators, floor...
-
Scoping [4.1.3(13)]
Scoping [4.1.3(13)] ADAAG covers elements that are fixed or built-in, including those bolted to floors or walls....
-
4.13.9* DOOR HARDWARE
Mount no hardware required for accessible door passage higher than 48 in (1220 mm) above finished floor....