Yes, spaces used by employees for purposes other than work, including restrooms, break rooms, locker rooms, lounges, and parking must be fully accessible....
Search Results "Resident Sleeping Room"
-
Are employee restrooms and break rooms required to be accessible?
-
222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with 803....
-
11B-213.2.1 Unisex (single-use or family) toilet and unisex bathing rooms
Unisex toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
Accessible Transient Lodging [9]
Accessible Transient Lodging [9] Section 9 covers a range of facilities that provide sleeping accommodations but that are not used as permanent residences....
-
Turning Space: ADA Standard Section 603.2.1
Section 603.2.1 covers the current ADA Standards for turning space in toilet and bathing rooms.
-
Section 35.151(h) Medical care facilities
Section 35.151(h) Medical care facilities In the 1991 title II regulation, there was no provision addressing the dispersion of accessible sleeping rooms in medical care facilities....
-
Section 36.406(g) Medical Care Facilities
Section 36.406(g) Medical Care Facilities In the 1991 title III regulation, there was no provision addressing the dispersion of accessible sleeping rooms in medical care facilities....
-
Guarantees of reservations for accessible guest rooms. (Section-by-Section Analysis)
Guarantees of reservations for accessible guest rooms....
-
11B-603.2.1 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
Turning Space: ADA Standard Section 612.3
Section 612.3 covers the current ADA Standards for turning space within saunas and steam rooms.
-
11B-603.2.1 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be...
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be...
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
4.1.6(1)(g)
(g) Mechanical rooms and other spaces which normally are not frequented by the public or employees of the building or facility or which by nature of their use are not required by the Architectural...