Search Results "Pit Toilet"
- Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance – Drawing from the U.S. Access Board
-
216 Signs
The guidelines also include provisions specific to certain elements and spaces, including parking, entrances, means of egress, and toilet and bathing rooms....
-
Question 20
YES/NO 20. Is the required floor and wall space inside public restrooms and fitting rooms blocked by obstacles such as trash cans, chairs, or...
-
Question 17
YES/NO 17. Are the signs for the accessible restrooms and fitting rooms still readable and mounted next to the latch side of the door, at 5 feet to...
-
§ 35.151(b)(4)(i)(A)
(A) Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, and corridors are not areas containing a primary function. ...
-
§ 38.107(b)
(b) Restrooms required to be accessible shall be in close proximity to at least one seating location for persons using mobility aids and shall be connected to such a space by an...
-
§ 35.151(b)(4)(i)(A)
(A) Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, and corridors are not areas containing a primary function....
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
6.1(4)(b)
Where toilet/bathrooms are part of patient bedrooms which are added or altered and required to be accessible, each such toilet/bathroom shall comply with 6.4....
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
Character Height: ADA Standard Section 703.5.5
Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further...
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing...
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing...
-
6.1(4)(a)
Where toilet/bathrooms are part of patient bedrooms which are added or altered and required to be accessible, each such patient toilet/bathroom shall comply with 6.4....
-
11B-604.8.1.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
- Access Board: Toilet Rooms
- Figure 604.8.1.1 Size of Wheelchair Accessible Toilet Compartment – Drawing from the U.S. Access Board
-
Single User Restroom Accessibility
Specific to California, you observe Health and Safety Code Section 118600 which indicates all single-user toilet facilities in any business establishment, place of public accommodation,...
-
Hadrian Inc. Toilet Partition Floor Mounted Privacy Screens
Requires the Premium User plan or above. (Login or upgrade your account!)