This example of a retail facility shows how scoping requirements for certain elements and spaces (sales counters and fitting rooms) apply and indicates employee work areas....
Search Results "Pick-Up Counter"
Commonly Searched Documents
-
Example: Retail Facility
-
B. Assistive Listening Systems
the most feasible type of listening system for people who use hearing aids equipped with “T-coils”, but people without hearing aids or those with hearing aids not equipped with inductive pick-ups...
-
Pass Through Kitchen
Clearances for pass through kitchens address counters, appliances, or cabinets on two opposing sides....
-
3) Restaurants
Contains requirements for counters and bars, access aisles, food service lines, tableware and condiment areas, raised speaker's platforms, and vending machine areas (but not controls)....
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
226.1 General
Sales counters and service counters shall not be required to comply with 902. 2....
-
K5
If the operating controls are set back 10 to 24 inches from the front edge of the counter or table are they no higher than 46 inches above the floor?...
-
Voting Area
If voters are expected to vote at counters or tables, there should be a writing surface that provides knee and toe clearance so that a voter who uses a wheelchair may sit at and use the...
-
4.34.6.7* OVENS
Ovens shall be of the self-cleaning type or be located adjacent to an adjustable height counter with knee space below (see Fig. 52)....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
Current Accessibility Guidelines That Apply to the Forest Service
The Forest Service and those working with or for the Forest Service on National Forest System land must comply with the following enforceable guidelines and standards when designing,...
-
§382.43(c)(4)
., by telephone or at the ticket counter) as follows:...
-
§ 382.43(c)(4)
., by telephone or at the ticket counter) as follows:...
-
Adaptability
The ability of certain building spaces and elements, such as kitchen counters, sinks, and grab bars, to be added or altered so as to accommodate the needs of individuals with or without...
- Clarity XLC3.4 DECT 6.0 Extra Loud Big Button Speakerphone with Talking Caller ID and ClarityLogic™
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
4.32.3 Knee Clearances
If seating for people in wheelchairs is provided at tables or counters, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided (see Fig....
-
ADAPTABILITY
The ability of certain building spaces and elements, such as kitchen counters, sinks, and grab bars, to be added or altered so as to accommodate the needs of either disabled or nondisabled...
-
4.34.6.1* CLEARANCE
Clearances between all opposing base cabinets, counter tops, appliances, or walls shall be 40 in (1015 mm) minimum, except in U-shaped kitchens, where such clearance shall be 60 in (1525...
-
Knee and Toe Space
If the forward reach to operable parts extends over an obstruction, such as a counter, clearances for toes and knees is required below....
-
§ 382.39 Provision of services and equipment
., directly pick up the passenger's body in the arms of one or more carrier personnel to effect a change of level that the passenger needs to enter or leave the aircraft)....
-
804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1525...