Visible indicators shall comply with Section 11B-411.4.8.1.
Search Results "Patient in Standing Position"
Commonly Searched Documents
-
11B-411.4.8.1 Visible indicators
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. Exception: For elevators that have a rated speed of 200 feet per...
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. Exception: For elevators that have a rated speed of 200 feet per...
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1.
-
11B-407.4.8.1.1 Size
Characters shall be ½ inch (12.7 mm) high minimum.
-
Clear Space Evaluation
As a result subjects positioned themselves in a wide variety of locations about the transfer station. ...
-
M303.2.2 Width (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients seated in a wheelchair provide a wheelchair space that was at least 36 inches wide....
-
2. Equipment Clearances for Breast Platforms
The MDE NPRM proposed knee and toe clearance requirements for diagnostic equipment used by patients seated in wheelchairs that paralleled the knee and toe clearance requirements from the...
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep...
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
11B-223.3 Long-term care facilities
In licensed long-term care facilities, including skilled nursing facilities, intermediate care facilities and nursing homes, at least 50 percent, but no fewer than one, of each type of patient...
-
11B-223.3 Long-term care facilities
In licensed long-term care facilities, including skilled nursing facilities, intermediate care facilities and nursing homes, at least 50 percent, but no fewer than one, of each type of patient...
-
11B-223.3 Long-term care facilities
In licensed long-term care facilities, including skilled nursing facilities, intermediate care facilities and nursing homes, at least 50 percent, but no fewer than one, of each type of patient...
-
a. Knee and Toe Clearance
The requirements are intended to ensure that there is adequate space for a patient seated in a wheelchair to position underneath the equipment and align themselves against the breast platform...
-
M303.2.3.1 Front or Rear Entry
Where wheelchair space entry and exit is provided at only one end (front or rear) the wheelchair space shall be 48 inches (1220 mm) deep minimum.
-
M303.2.3.3 Side Entry
Where wheelchair space entry is only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum.
-
M303.2.3.2 Pass Through Entry
Where wheelchair space entry and exit permits pass through from one end to the other, the wheelchair space shall be 40 inches deep (1015 mm) minimum.
-
Physical Access
Resources found at http://www.hfcdihp.org/products.html Choosing and Negotiating an Accessible Facility Location Improving Accessibility with Limited...
-
Physical Access
# Physical Access Yes No Unsure Comments and follow up C. We have completed a physical access survey of our health care providers’...
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
[See subsections ...]
-
907.2.6.1 Group I-2
Exceptions: Corridor smoke detection is not required where patient sleeping rooms are provided with smoke detectors that comply with UL 268....
-
5.8.2.1 Height of Breast Platform at Time of Measurement
However, the top surface of the breast platform is a well-defined surface, and defines where the patient’s chest will be during the exam....