F248 Beach Access Routes
-
R309.2.1 Wide Sidewalks
R309.2.1 Wide Sidewalks. Where the width of the adjacent sidewalk or available right-of-way exceeds 4.3 m (14.0 ft), an access aisle 1.5 m (5.0 ft) wide minimum shall be provided at...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Power Chair
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching...
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp. The slope of the turning space in all directions shall be...
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp. The slope of the turning space in all directions shall be...
-
1. New Curb Ramp Construction and Alterations
., a ramp aligned in parallel to the cross-walk) or at least one curb ramp per corner. RT 1978:12-1980:1, 1981:16-1990:19; DTX G07, DTX H04 [000002, 000004]....
- Access Board: Alternate Type Roll In Shower Stalls
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
-
11B-705.1.2.2.2.1 One entrance/exit point
Existing parallel curb ramps with detectable warnings in compliance with the code requirements in effect at the time of installation shall not be required to provide a minimum 36 inches...
-
11B-233.3.1.2.6.5 Additional requirements.
Grab bar reinforcement complying with Sections 11B-809.10.5.2, 11B-809.10.6.4, or 11B-809.10.7.3. 2. Interior door opening width complying with Section 11B-404.2.3. 3....
-
Grab bar protocol
When transferring to a lower height, with the front grab bar available, and without side guard, 51% (59/115), CI[42%,60%] used the front bar, and 20% (23/111), CI[12%,25%] could transfer...
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Where mirrors or towel bars are provided, no less than one of each shall comply with this section....
- Access Board: Standard Roll In Shower Stalls
-
Chapter 4: Implications for standards and design
[See subsections ...]
-
406.4 Landings
Landings shall be provided at the tops of curb ramps. The landing clear length shall be 36 inches (915 mm) minimum. The landing clear width shall be at least as wide as the curb...
-
F208 Parking Spaces
[See subsections ...]
-
Forward and Side Approaches
At most elements, clear floor space can be positioned for either a forward approach or a side approach. A forward approach is required at some elements, such as drinking fountains...
-
809.2.5 Bedrooms in Emergency Transportable Housing Units
The clear floor space must be positioned for a parallel approach to the side of the bed and must be on an accessible route....
-
Front grab bar protocol
Two conditions in random order were tested: 1) front grab bar and no side guard and 2) both front grab bar and side guard present in the setup. ...