i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door and exit...
Search Results "Exit Enclosure"
Commonly Searched Documents
-
7(2)(a)(i)
-
A7.3 Check-out Aisles
In order to use a check-out aisle (7.3), customers must enter a defined area (an aisle) at a particular point, pay for goods, and exit at a particular point....
-
4.10.9 Floor Plan of Elevator Cars
The floor area of elevator cars shall provide space for wheelchair users to enter the car, maneuver within reach of controls, and exit from the car....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
The floor area of elevator cars shall provide space for wheelchair users to enter the car, maneuver within reach of controls, and exit from the car....
-
220 Automatic Teller Machines and Fare Machines
If self-service fare collection devices are provided for the use of the general public, at least one accessible device for entering, and at least one for exiting, unless one device serves...
- Builders Hardware Manufacturers Association (BHMA)
-
PATH OF TRAVEL
[DSA-AC] An identifiable accessible route within an existing site, building or facility by means of which a particular area may be approached, entered and exited, and which connects a particular...
-
238.3 Practice Putting Greens, Practice Teeing Grounds, and Teeing Stations at Driving Ranges
percent, but no fewer than one, of practice putting greens, practice teeing grounds, and teeing stations at driving ranges shall be designed and constructed so that a golf car can enter and exit...
-
B4
is there vertical clearance of at least 98 inches (8 feet - 2 inches) for the vehicle route to the parking space, the parking space, the access aisle, and along the vehicle route to the exit...
-
A4.34.2 MINIMUM REQUIREMENTS
An accessible second exit to dwelling units provides an extra margin of safety in a fire....
-
§ 38.31(c)
Such light(s) shall be shielded to protect the eyes of entering and exiting passengers....
-
1009.9 Signage
Where exit sign illumination is required by Section 1013.3, the signs shall be illuminated....
-
Re: Stair widths
This 48 inches theoretically provides enough room for two or three people to carry a person with mobility issues down to the level of exit discharge. ...
- American Bath Enterprises, Inc. AccessaBath Shower System
- BEA Inc. MS11 Touchless Door Access (Wave to Open)
-
Emergency Planning
detail procedures for providing evacuation assistance to people who would have difficulty or who would be unable to: Use stairwells, Hear alarms, See exits...
-
1009.9 Signage
Where exit sign illumination is required by Section 1011.3, the signs shall be illuminated....
-
11B-240.2.2 Elevated play components
Some play components that are attached to a composite play structure can be approached or exited at the ground level or above grade from a platform or deck....
- Neo-Metro Commercial Wall Mounted Pat Basin Featuring Dyson® Airblade™ Tap/Hand Dryer
-
M305.3.1.2 Diagnostic Equipment Containing a Wheelchair Space
On diagnostic equipment containing wheelchair spaces with one entry that also serves as the exit, the length of the gripping surface of horizontal standing supports shall be equal to or...
-
Surprise Drills
., blocked paths or exits), forcing people to use alternative routes. Performance of these drills should also be evaluated and feedback given to all participants. ...
-
Door Closers [4.13.10]
it may be difficult for a person with a disability to open a door against the resistance offered by a closer, it is important that the closing action be slow enough to allow entry and exit...
-
Elevators with Standby Power [IBC §1007.4 (2003), §1003.2.13.3 (2000)]
In buildings with four or more stories above or below the level of exit discharge, at least one accessible means of egress must be an elevator with standby power and emergency signaling...
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....