Furnished with heavy cast brass grid drain strainer, elbow and 1 1/4" 17GA seamless tubular offset tailpiece. ADA compliant. 8 3/4" x 5 1/8" OD.
Search Results "Clear Floor Space"
- McGuire Manufacturing Co., Inc. 155WC: Offset Lavatory Strainer
- IPS Corporation Truebro® Lav Shield® Protective Lavatory Enclosure
- McGuire Manufacturing Co., Inc. PW1000WC: 1 1/2" Offset Sink
- McGuire Manufacturing Co., Inc. ProDrainWC: Lavatory Strainer Less Overflow
- Zurn Industries Rigid Lavatory Enclosure - Vandal Gard
- McGuire Manufacturing Co., Inc. 1152WC: Offset with 152 Wide Top Strainer
- McGuire Manufacturing Co., Inc. 1000WC: Offset Strainer - Offset Only
-
T-Shaped Space: ADA Standard Section 304.3.2
Section 304.3.2 covers the current ADA Standards for t-shaped turning space.
-
R404.1 General
Clear spaces shall comply with R404. Advisory R404.1 General....
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided....
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture....
- Magnuson Group RIGA Series Waste Receptacle
-
606.2 Clear Floor Space
606.2 Clear Floor Space. A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
-
1. Accessible toilet
Accessible toilet with rear and side grab bars, clear floor space for wheelchair transfer, and an accessible flush valve....
-
Side Approach
Side Approach The maximum reach depth for a high (54 inch maximum) reach is 10 inches, measured from the clear floor space....
-
11B-802.1.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-802.1.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
R302.4 Passing Spaces
R302.4 Passing Spaces. Where the clear width of pedestrian access routes is less than 1.5 m (5.0 ft), passing spaces shall be provided at intervals of 61 m (200.0 ft) maximum....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space. ...
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADA Standards] 805.3 Clear Floor or Ground Space....
-
Fixtures
Fixtures TAS 604.3.2 also allows the clear floor space and clearances required at other “fixtures” to overlap the water closet clearance....
-
2. Accessible lavatory with knee and toe space
Accessible lavatory with knee and toe space below, faucet controls usable with a loosely closed fist, clear floor space for front approach, and lowered mirror....