[Sec. 382.41(g)(1)] If (i) the battery on the passenger’s wheelchair has been labeled by the manufacturer as non-spillable or (ii) the battery-powered wheelchair with a spillable battery...
Search Results "9-1-1 Service"
-
Battery-powered Wheelchairs
-
408.4.1 Car Dimensions and Doors
EXCEPTIONS: 1....
-
Americans with Disabilities Act (ADA) of 1990 (with amendments issued through 2008)
Following is the current text of the Americans with Disabilities Act of 1990 (ADA), including changes made by the ADA Amendments Act of 2008 (P.L. 110-325), which became effective on January 1,...
-
E205.3 Agency Official Communication
conform to the accessibility requirements specified in E205.4 when such content constitutes official business, and is communicated by an agency through one or more of the following: 1....
-
Temporary Solutions for Election Day
Temporary Solutions for Election Day Interior Hallways and Corridors to Voting Area Problem 1: One or more steps along hallway to voting area block access....
-
404.2.3 Doorways - Clear Width
EXCEPTIONS: 1. In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
6.1(4)(a)
The percentage of accessible rooms provided shall be consistent with the percentage of rooms required to be accessible by the applicable requirements of 6.1(1), 6.1(2), or 6.1(3), until...
-
Openings in Trail Surfaces
If even the three-fourths of an inch deviation is not enough, General Exception 1 allows achieving trail surface opening requirements to the extent practicable if a condition for an exception...
-
404.2.3 Doorways - Clear Width
EXCEPTIONS: 1. In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
3.1.4.1 Width of Non-RV Campsite Vehicle Parking Areas
Exception 1....
-
REFERENCES
1. Boninger, M.L., et al., Investigating neck pain in wheelchair users. Am J Phys Med Rehabil, 2003. 82(3): p. 197-202. 2....
-
§100.205(d)
(d) The application of paragraph (c) of this section may be illustrated by the following examples: Example (1): A developer plans to construct a 100 unit condominium apartment building...
-
Calculation of Percentages
wheelchair accessible water closets (16” – 18” centerline from side walls or partitions), specifying to the midpoint of the range (17”) will accommodate any construction variations up to 1”...
-
[ADA Title III] Readily achievable
In determining whether an action is readily achievable factors to be considered include -- (1) The nature and cost of the action needed under this part; (2) The overall financial...
-
10 - foot straightedge method
When used as a specification or requirement, a maximum deviation in length under the straightedge is given, such as "no point shall exceed 1/4 inch under a 10 - foot straightedge."...
-
JURISDICTION
. § 12131(1). The Department is authorized under 28 C.F.R....
-
§ 38.23(b)(13) Handrails
handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than 1/...
-
§ 38.95(b)(13) Handrails
handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than 1/...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Where a door is provided the symbol shall be mounted within 1 inch (25 mm) of the vertical centerline of the door....
-
§ 38.125(b)(13) Handrails
handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than 1/...
-
§ 38.83(b)(13) Handrails
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than 1/...
-
11B-404.2.3 Clear width
Exceptions: 1. In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
An accessible route to a building entrance is impractical due to unusual characteristics of the site when: 1....
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...