This Agreement is limited to the Museum described in Paragraph 4 above, and does not apply to any other design or construction project of or related to the Museum....
Search Results "Space Limitation"
Commonly Searched Documents
-
E. IMPLEMENTATION AND ENFORCEMENT
-
INSTRUCTIONS FOR INVESTIGATORS
[see Questions 1-4] Did the Respondent request documentation of the Charging Party's disability and/or functional limitations? If yes, was the documentation provided?...
-
"Video Remote Interpreting (VRI) Services'' (Section-by-Section Analysis)
Many commenters strongly recommended limiting the use of VRI to circumstances where it will provide effective communication....
-
1. Evolving Approach to Covered Electronic Content
However, one commenter expressed concern that limiting coverage of electronic content to certain specific categories could lead to a non-inclusive work environment for employees and that...
-
Section 36.301 Eligibility Criteria (Section-By-Section Analysis and Response to Comments)
segregative eligibility criteria that would bar, for example, all persons who are deaf from playing on a golf course or all individuals with cerebral palsy from attending a movie theater, or limit...
-
Regulatory Process Matters
This estimate likely understates the actual spending by the Federal government because it is limited to the GSA data....
-
Minimum Rear Wall Required.
Using the 2010 ADA Standards for Accessible Design, the minimum bench length would be 42" and the width of the clear floor space adjacent to the end of the bench would be 30"....
-
Stair widths
I am having an issue on a project that has 42" high guardrails (due to a >30" drop off on either side) which are spaced exactly 48" apart....
-
Existing elevator cab size
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
11B-222.1 General
Some designs include private changing facilities that are close to core areas of the facility, while other designs use space more economically and provide only group dressing facilities....
-
1117B.5.6
Dots shall be 1/10 inch (2.54 mm) on center in each cell with 2/10-inch (5.08 mm) space between cells, measured from the second column of dots in the first cell to the first column of dots...
-
R302.3.2 Shared Use Paths
access routes to be 4 feet wide minimum, except R302.3.1 would require pedestrian access routes within medians and pedestrian refuge islands to be 5 feet wide minimum to allow for passing space...
-
Accessible Amusement Rides
Other provisions contained in ADAAG address elements commonly found at an amusement park or theme park, such as accessible vehicle parking spaces, exterior accessible routes, and toilet...
-
5.5.1 Armrest Provision for M302
Armrests serve a similar function, and occupy the same physical space, as the transfer supports as described in the NPRM....
-
4. My pool already existed before the effective date of the new rule. What am I required to do to provide pool access to customers with mobility disabilities?
The 2010 Standards for pool lifts require lifts to be fixed and to meet additional requirements for location, size of the seat, lifting capacity, and clear floor space....
-
3. If I comply with the California accessibility requirements, am I in compliance with ADA?
Under the CBC, however, if you change the use of a room or space without submitting for a permit, the accessibility requirements of the CBC still applies....
-
4.1.4(4) ASSEMBLY
A room or space used for assembly purposes by less than fifty (50) persons and accessory to another occupancy shall be included as a part of that major occupancy....
-
PRIORITIES
These measures include, for example, installing an entrance ramp, widening entrances, and providing accessible parking spaces....
-
11B-222.1 General
Some designs include private changing facilities that are close to core areas of the facility, while other designs use space more economically and provide only group dressing facilities....
-
11B-222.1 General
Some designs include private changing facilities that are close to core areas of the facility, while other designs use space more economically and provide only group dressing facilities....
-
11B-215.1 General
Unlike audible alarms, visible alarms must be located within the space they serve so that the signal is visible....
-
Site Arrival Points: ADA Standard Section 206.2.1
Section 206.2.1 covers the scoping requirements for site arrival points of accessible routes in the most current ADA Standards.
-
1. Public Rights-of-Way
The guidelines cover the minimum scoping and technical requirements for various spaces and elements in the public right-of-way, such as pedestrian access routes, which ensure the accessibility...
-
We often see projects of gas station replacing old fuel dispensers with access compliance fuel dispensers (reach range, operable parts, point-of-sale). According to Section 11B-202.4, Exception 10, these projects would be required to comply with accessibility for primary accessible path to inside the convenient store at the gas station, public restrooms, drinking fountains, public telephones, and signs (with 20-percent limit of adjusted construction cost). Is my understanding correct regarding the replacement of old/addition of new fuel dispensers?
RESPONSE: Exception 10 to Section 11B-202.4 is only applicable to the installation of EVCS – the exception does not apply to gasoline filling equipment. However, Section 11B-202.4...