Accessible spaces shall be provided with not less than one accessible means of egress....
Search Results "Shower Clear Floor Space"
-
1003.2.13 Accessible means of egress
-
Single-User Toilet Rooms: Split Plumbing
While the knee and toe clearance required at lavatories may allow a forward approach to door hardware, if placed in the maneuvering space, lavatories interfere with wheelchair maneuvering...
-
R204.2 Sidewalks
The pedestrian access route shall connect to accessible elements, spaces, and facilities required by this document and to accessible routes required by section 206.2.1 of appendix B to 36...
-
1009.7.2 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever...
-
1009.7.2 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point not less than 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the...
-
Transfer Surface Size: Equipment Used by Patients in Supine, Prone, or Side-Lying Position (M301.2.2)
minimum width and 15 inches minimum depth also are generally consistent with the dimensions specified in the 2004 ADA and ABA Accessibility Guidelines for rectangular seats in roll-in showers...
-
III-1.7000 Relationship to title II
The first floor is leased as commercial space to a restaurant, a newsstand, and a travel agency....
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor. ...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
1.9.1.2
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar, with the opening of the disposal unit 19” minimum (483 mm) above the finish floor....
-
1.9.1.2 Application
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
§ 38.107(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
§ 38.123(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
§ 38.159(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....
-
§ 38.95(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
- Pilot Rock T300/T400 Series Round, Pedestal Table With CONTOUR Bench Seats - Using Expanded Steel
- Seton Reserved Parking Sign (With Graphic) and Post
- Elkay Filtered EZH2O® Bottle Filling Station with Single ADA Cooler
- Landscape Forms Inc. Arcata Collection Benches
- Landscape Forms Inc. Metro 40 Rest Bench
-
711.2 Installation details
The space between the item contained in the sleeve and the sleeve itself and any space between the sleeve and the assembly penetrated shall be protected in accordance with this section....