This time savings is due to the revised water closet clearance standard, which permits, among other things, greater flexibility in terms of access to the toilet by parallel or side transfer...
Search Results "Accessible Element"
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. #28)
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. # 28)
This time savings is due to the revised water closet clearance standard, which permits, among other things, greater flexibility in terms of access to the toilet by parallel or side transfer...
-
Access for All: Five Years of Progress A Report from the Department of Justice on Enforcement of the Americans with Disabilities Act
[See subsections ...]
-
49 CFR Part 38 - ADA Accessibility Specifications for Transportation Vehicles (with amendments issued through 2014)
Authority: 42 U.S.C. 12101-12213; 49 U.S.C. 322. Source: 56 FR 45756, Sept. 6, 1991, unless otherwise noted.
-
3. Exception to Ramp Running Slope
The Access Board explained in the MDE NPRM preamble that this provision is consistent with the 2004 ADA and ABA Accessibility Guidelines’ technical criteria for changes in level....
-
4. Comparison of Proposed Technical Provisions Applicable to Shared Use Paths and AASHTO Guide
Where pedestrian access routes are not contained within a street or highway right-of-way, the grade of pedestrian access routes shall be 5 percent maximum....
-
U.S. Access Board - Supervisory Technical Services Officer
Access Board seeks a Supervisory Technical Services Officer (GS 15) to serve in its Office of Technical and Information Services. Applications are due by February 25, 2022....
-
E.2. - Where an agency uses a best value "trade-off" source selection process, may it trade off applicable technical provisions of the Access Board’s standards where an offer provides strong technical merit, strong past performance, or a lower price?
The Access Board’s technical provisions are mandatory requirements that must be met (directly or through equivalent facilitation) unless (a) the product or service (if it is a commercial...
- Figure 404.2.4.2(b) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- Figure 404.2.4.2(d) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- Figure 404.2.4.1(e) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Pull Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(f) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Push Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(h) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Pull Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(j) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Push Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(d) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Pull Side – Drawing from the U.S. Access Board
- Figure 404.2.4.2(c) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- Figure 404.2.4.1(b) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side – Drawing from the U.S. Access Board
-
11B-308.4 Suggested reach ranges for children
Where building elements such as coat hooks, lockers, or operable parts are designed for use primarily by children, the suggested dimensions of Table 11B-308.4 shall be permitted....
-
11B-304.2 Floor or Ground Surfaces
ground spaces, turning spaces, and in similar spaces where people using wheelchairs and other mobility devices must park their mobility aids such as in wheelchair spaces, or maneuver to use elements...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
304.2 Floor or Ground Surfaces
ground spaces, turning spaces, and in similar spaces where people using wheelchairs and other mobility devices must park their mobility aids such as in wheelchair spaces, or maneuver to use elements...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-304.2 Floor or Ground Surfaces
ground spaces, turning spaces, and in similar spaces where people using wheelchairs and other mobility devices must park their mobility aids such as in wheelchair spaces, or maneuver to use elements...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...