Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
Search Results "Vertical Dispersion"
-
11B-903.6 Structural strength
-
1017.5 Tread Obstacles
The vertical alignment of joints in concrete, asphalt, or board surfaces on trails can be tread obstacles....
-
Edge Protection: ADA Standard Section 405.9
Section 405.9 covers the current ADA Standards for edge protection at ramps.
-
Slope Ratio
Slope Ratio—A ratio of vertical distance to horizontal distance or rise to run....
-
221.9 Stadium Style Movie Theaters
at least one of the following criteria: (i) It is located within the rear 60% of the seats provided in an auditorium; or (ii) It is located within the area of an auditorium in which the vertical...
-
Is there a minimum distance between changes in level?
Such level changes may need to be in close proximity, such as at raised thresholds (otherwise a minimum 48” separation will provide enough wheelchair space so that only one vertical change...
-
Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations: ADA Standard Section 233.2
Section 233.2 covers scoping requirements in the current ADA Standards for residential dwelling units provided by entities subject to HUD Section 504 Regulations.
-
1132A.4.1, Item 1
Thresholds with a change in height of not more than ¼ inch (6.35 mm) may be vertical....
-
1132A.4.1, Item 1
Thresholds with a change in height of not more than ¼ inch (6.35 mm) may be vertical....
-
A4.1.3(10)
When more than one drinking fountain on a floor is required to comply with 4.15, those fountains should be dispersed to allow wheelchair users convenient access....
-
Priority 1: Approach & Entrance
Word Fillable Form (1.5MB) Word Non-Fillable Form (1.3MB) PDF Non-Fillable Form (0.8MB)
-
11B-810.2.3 Connection
shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped at 35 degrees maximum from vertical...
-
11B-810.2.3 Connection
shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped at 35 degrees maximum from vertical...
-
T402.9 Transitions
Vertical surface discontinuities at transitions from boarding and alighting areas to ramps and bridgeplates shall comply with T302.4....
-
1003.2.12.1 Height
Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....
-
1003.2.12.1 Height
Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....
-
11B-221.2.1.5 Stadium-style movie theaters
satisfy at least one of the following criteria: Located within the rear 60 percent of the seats provided in the theater; or Located within the area of the theater in which the vertical...
-
11B-303.3 Beveled
A change in level of 1/2 inch (13 mm) is permitted to be 1/4 inch (6.4 mm) vertical plus 1/4 inch (6.4 mm) beveled....
-
907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
11B-303.3 Beveled
A change in level of 1/2 inch (13 mm) is permitted to be 1/4 inch (6.4 mm) vertical plus 1/4 inch (6.4 mm) beveled....
-
907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces....
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....