, (b) including wheelchair spaces as an integral part of the fixed seating plan, (c) providing the appropriate depth for cross aisles to wheelchair spaces and (d) satisfying applicable dispersion...
Search Results "Vertical Dispersion"
-
2.3
-
11B-232.2 General holding cells and general housing cells
Accessible cells or rooms should be dispersed among different levels of security, housing categories, and holding classifications (e.g., male/female and adult/juvenile) to facilitate access...
-
F232.2 General Holding Cells and General Housing Cells
Accessible cells or rooms should be dispersed among different levels of security, housing categories, and holding classifications (e.g., male/female and adult/juvenile) to facilitate access...
-
11B-232.2 General holding cells and general housing cells
Accessible cells or rooms should be dispersed among different levels of security, housing categories, and holding classifications (e.g., male/female and adult/juvenile) to facilitate access...
-
10) Assembly areas
When the area has over 300 seats, there are requirements for dispersal of wheelchair seating....
-
11B-232.2 General holding cells and general housing cells
Accessible cells or rooms should be dispersed among different levels of security, housing categories, and holding classifications (e.g., male/female and adult/juvenile) to facilitate access...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
Slope Ratio
Slope Ratio—A ratio of vertical distance to horizontal distance or rise to run....
-
1017.5 Tread Obstacles
The vertical alignment of joints in concrete, asphalt, or board surfaces on trails can be tread obstacles....
-
Edge Protection: ADA Standard Section 405.9
Section 405.9 covers the current ADA Standards for edge protection at ramps.
-
11B-233.3 Public housing facilities
Further, the residential dwelling units provided must be dispersed according to HUD's Section 504 criteria....
-
Is there a minimum distance between changes in level?
Such level changes may need to be in close proximity, such as at raised thresholds (otherwise a minimum 48” separation will provide enough wheelchair space so that only one vertical change...
-
221.9 Stadium Style Movie Theaters
at least one of the following criteria: (i) It is located within the rear 60% of the seats provided in an auditorium; or (ii) It is located within the area of an auditorium in which the vertical...
-
1132A.4.1, Item 1
Thresholds with a change in height of not more than ¼ inch (6.35 mm) may be vertical....
-
1132A.4.1, Item 1
Thresholds with a change in height of not more than ¼ inch (6.35 mm) may be vertical....
-
Priority 1: Approach & Entrance
Word Fillable Form (1.5MB) Word Non-Fillable Form (1.3MB) PDF Non-Fillable Form (0.8MB)
-
11B-810.2.3 Connection
shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped at 35 degrees maximum from vertical...
-
11B-810.2.3 Connection
shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped at 35 degrees maximum from vertical...
-
T402.9 Transitions
Vertical surface discontinuities at transitions from boarding and alighting areas to ramps and bridgeplates shall comply with T302.4....
-
A4.1.3(10)
When more than one drinking fountain on a floor is required to comply with 4.15, those fountains should be dispersed to allow wheelchair users convenient access....
-
Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations: ADA Standard Section 233.2
Section 233.2 covers scoping requirements in the current ADA Standards for residential dwelling units provided by entities subject to HUD Section 504 Regulations.
-
1003.2.12.1 Height
Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....
-
1003.2.12.1 Height
Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....