The final Guidelines also provide that at the primary entry door to a dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such as concrete...
Search Results "Unit of Measurement"
Commonly Searched Documents
-
(d) Outside surface at entry door
-
Van Accessible Parking Spaces [§502.1 - 502.5]
Van Accessible Parking Spaces [§502.1 - 502.5] At least one space for every 6 or fraction of 6 accessible spaces must be van accessible. Van spaces provide an additional 3...
-
11B-708.4.2 Residential dwelling unit interface
11B-708.4.2 Residential dwelling unit interface....
-
608.3 Grab Bars (Exception 2)
608.3 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed in shower compartments in residential dwelling units required to provide mobility features...
-
607.4 Grab Bars (Exception 2)
607.4 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed at bathtubs in residential dwelling units required to provide mobility features provided...
-
809.5.1 Building Fire Alarm System
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
11B-809.5.1 Building fire alarm system
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
809.5.1 Building Fire Alarm System
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
11B-809.5.1 Building fire alarm system
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
11B-809.5.1 Building fire alarm system
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
Water Closet Clear Floor Space in Toilet Compartments
The 48 inch specification measured from the leading edge of the water closet is derived from the ANSI A117.1-1992 standard....
-
1011.7 Outdoor Rinsing Showers
This section requires outdoor rinsing showers to provide at least one hand-held shower spray unit with a hose 59 inches long minimum....
-
11B-809.5.2.1 Activation
All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection....
-
F244.1 General
The terms camping facility, camping unit, and camp shelter are defined in F106.5....
-
1(1)(a) Separate ground floor unit entrances
(a) Separate ground floor unit entrances....
-
809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
11B-809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
11B-809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
11B-809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
The original site characteristics result in a difference in finished grade elevation exceeding 30 inches (762 mm) and 10 percent measured between an entrance and all vehicular or pedestrian...