The space between the side grab bar and the side wall in the toilet stall for persons with disabilities is 3c inches. ...
Search Results "Side Reach"
Commonly Searched Documents
-
Attachment J
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door....
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door....
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door....
-
T208.2.1 Doorways on One Side of vehicle
Where non-rail vehicles have doorways on one side, a passenger access route shall connect each wheelchair space to a doorway that provides a means of accessible boarding and alighting in...
- Pilot Rock UT Series Side Accessible Picnic Table Using Aluminum
- Pilot Rock XT Series Side Accessible Picnic Table Using Aluminum
-
3.2 Getting on the Table
Additional helpful features include an extra-wide top surface and higher weight capacity for larger people, adjustable side rails, positioning straps, and foot and leg supports that can...
-
M305.2.2.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M305.2.2.1 shall be 15 inches (380 mm) long minimum. Transfer supports shall be positioned along 13 ½ inches...
-
M305.2.4.1 Circular Cross Section
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
- IDeA Center: Transferring from Wheeled Mobility to MidMark's Barrier-Free Examining Table
-
PlayLSI Chimes Reach Panel Plan
Requires the Premium User plan or above. (Login or upgrade your account!)
-
FACTS APPLICABLE TO ALL CLAIMS
Even where curb ramps exist, many are improperly installed and/or maintained, lack a flush transition to the street, have excessively steep running, cross, and side slopes, are too narrow...
-
Comparison of Single-User Toilet Room “Pairs” With Fixtures Side-by-Side: Plan 1A and Plan 1B
Comparison of Single-User Toilet Room “Pairs” With Fixtures Side-by-Side: Plan 1A and Plan 1B 1991 Standards Plan-1A Pair: 1991 Standards with Out-Swinging...
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8...
-
M101.2 Application (Section-by-Section Analysis)
In the NPRM the Access Board proposed that the MDE Standards would be applied to diagnostic equipment based on the patient position the equipment is designed to support....
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
5.1.2 Transfer Surface High Height Recommendations for M301 and M302 The Committee recommends an adjustable height range with an upper height measuring at least 25...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual...
-
5.1.3 Transfer Surface Low Height
5.1.3 Transfer Surface Low Height. No agreement on final low height
-
5.1.2 Transfer Surface High Height
5.1.2 Transfer Surface High Height. The transfer surface should have an adjustable height range with an upper height measuring at least 25 inches.
-
5.1.1 Transfer Surface Height Adjustability Recommendation for M301 and M302
5.1.1 Transfer Surface Height Adjustability Recommendation for M301 and M302 The Committee recommends adjustable height in small, virtually continuous increments. Rationale for...
-
5.1.1 Transfer Surface Height Adjustability
5.1.1 Transfer Surface Height Adjustability. The transfer surface should have an adjustable height in small virtually continuous increments.