Where the lift is designed to deploy with its long dimension parallel to the vehicle axis and which pivots into or out of the vehicle while occupied (i.e., “rotary lift”), the requirements...
Search Results "Portable Patient Lift"
Commonly Searched Documents
-
§ 38.159(b)(2)(ii) Exception
-
Breast Platform [M303.4.1]
Another member emphasized the importance of considering patients of short stature in addition to considering patients seated in a wheelchair....
-
11B-1009.2.5 Seat width
The seat shall be 16 inches (406 mm) wide minimum.
-
1009.2.5 Seat Width
The seat shall be 16 inches (405 mm) wide minimum.
-
1009.2.5 Seat Width
The seat shall be 16 inches (405 mm) wide minimum.
-
Armrests M302.3.2
Armrests M302.3.2 Armrests are recommended but not required. If provided armrests cannot interfere with transfer supports during the transfer. Dual transfer support/armrest...
-
1009.2.5 Seat Width
1009.2.5 Seat Width. The seat shall be 16 inches (405 mm) wide minimum.
-
Incidental Rooms and Spaces
These can include work areas such as equipment control rooms, projection booths, radio and news booths, press boxes, and other occupiable spaces of incidental use where the maximum...
-
11B-1009.2.5 Seat width
The seat shall be 16 inches (406 mm) wide minimum.
-
11B-1009.2.5 Seat width
The seat shall be 16 inches (406 mm) wide minimum.
-
T502.2 Doorways with Lifts, Ramps or Bridgeplates
The vertical clearance at doorways with lifts, ramps or bridgeplates shall comply with T502.2....
-
M305.2.5 Surface Hazards (Section-by-Section Analysis)
were submitted on this issue, but the MDE Advisory Committee voiced concern about surface hazards stating, “gripping surface configurations must provide an effective and safe surface for patients...
-
11B-805.2 Patient bedrooms and resident sleeping rooms
Patient bedrooms and resident sleeping rooms required to provide mobility features shall comply with Section 11B-805.2....
-
11B-805.2 Patient bedrooms and resident sleeping rooms
Patient bedrooms and resident sleeping rooms required to provide mobility features shall comply with Section 11B-805.2....
-
11B-805.2 Patient bedrooms and resident sleeping rooms
Patient bedrooms and resident sleeping rooms required to provide mobility features shall comply with Section 11B-805.2....
-
Figure M3: Overview of M302 Diagnostic Equipment for Use by a Patient in a Seated Position
[See subsections ...]
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
Discussion: The Access Board is considering whether the following technical criteria would be appropriate for the location and size of transfer supports on diagnostic equipment used by patients...
-
10. I do not have a lift at my pool and it is not readily achievable to provide one now. Do I have to close the pool?
I do not have a lift at my pool and it is not readily achievable to provide one now. Do I have to close the pool? No....
-
5.1 Transfer Surface Height Recommendations
This height is also critical for patients who use mobility aids such as walkers and canes and may find it difficult to get up onto or down from an examination chair or table or imaging bed...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
Rationale for the recommendation Gripping surface configurations must provide an effective and safe surface for patients to hold onto....
-
F223.2.1 Facilities Not Specializing in Treating Conditions That Affect Mobility
In facilities not specializing in treating conditions that affect mobility, at least 10 percent, but no fewer than one, of the patient sleeping rooms shall provide mobility features complying...
-
M301.3.2 Leg Supports (Section-by-Section Analysis)
In the MDE NPRM, the Access Board proposed to place the requirements for stirrups on diagnostic equipment used by patients in the supine, prone, or side-lying position in M301....
-
M303.4.1 Breast Platforms
The height of the breast platform shall be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when in use by a patient seated in a wheelchair....
-
B. Summary of Major Provisions and Organization of Technical Criteria
The technical requirements for diagnostic equipment used by patients in the supine, prone, or side-lying position and diagnostic equipment used by patients in the seated position focus on...