(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top and bottom of the ramp segment and shall be parallel with the floor or ground surface (see Fig...
Search Results "Parallel Curb Ramp"
Commonly Searched Documents
-
4.8.5(2)
-
Spout Location [4.15.3]
The trajectory of water flow must be vertically "parallel" or "nearly parallel" to the face of the unit....
-
Clear Width [4.8.3]
The minimum dear width for ramps of 36 inches is measured between the leading edge of handrails. A maximum clear width is not specified....
-
11B-505.10 Handrail extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with Section 11B-505.10. Exceptions: 1. ...
-
11B-505.10 Handrail extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with Section 11B-505.10. Exceptions: 1. ...
-
11B-505.10 Handrail extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with Section 11B-505.10....
-
R407.6 Landings
Ramps shall have landings at the top and the bottom of each ramp run. Landings shall comply with R407.6....
-
2.1 Parking
Are there usable ramps or curb cuts onto the sidewalks? How far away from the entrance is the accessible parking?...
-
1.1.11 Ramp running slope
1.1.11 Ramp running slope....
-
R407.2 Running Slope
Ramp runs shall have a running slope between 5 percent minimum and 8.3 percent maximum. Advisory R407.2 Running Slope....
-
505.10 Handrail Extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with 505.10. EXCEPTIONS: 1....
-
505.10 Handrail Extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with 505.10. EXCEPTIONS: 1....
-
505.10 Handrail Extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with 505.10. EXCEPTIONS: 1....
-
505.10 Handrail Extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with 505.10. EXCEPTIONS: 1....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
11B-305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. ...
-
11B-305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. ...
-
1007.2 Accessible Routes
Where accessible routes intersect playing surfaces of holes, a 1 inch (25 mm) maximum curb shall be permitted for a width of 32 inches (815 mm) minimum. 3....
-
1007.2 Accessible Routes
Where accessible routes intersect playing surfaces of holes, a 1 inch (25 mm) maximum curb shall be permitted for a width of 32 inches (815 mm) minimum. 3....
-
T503.2 Ramps and Bridgeplates
When ramps or bridgeplates are deployed, the walking surface shall be lighted with 2 foot-candles (22 lux) minimum of illumination....
-
§ 36.403(e) Path of travel.
(e) Path of travel.
-
Sec.36.403(e) Path of travel
(e) Path of travel.
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....