Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
Search Results "Exercise Equipment"
Commonly Searched Documents
-
M303.3.3.4 Edge Protection
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
Section 1193.33 Accessibility and usability
Section 1193.33 Accessibility and usability Section 1193.33 requires that, where readily achievable, manufacturers must (1) provide a description of the accessibility and...
-
M302.2.5 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as...
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12.
-
Chapter M1 Application and Administration
[See subsections ...]
-
5. Edge Protection
The Access Board sought public input with question 30 in the MDE NPRM preamble, on whether there is diagnostic equipment with wheelchair spaces on raised platforms that does not provide...
- Midmark 625 Barrier-Free® Power Examination Table
- Midmark 623 Barrier-Free® Power Examination Table
- Midmark Ritter 222 Barrier-Free® Power Examination Table
- Midmark Ritter 223 Barrier-Free® Power Examination Table
-
Figure M3: Overview of M302 Diagnostic Equipment for Use by a Patient in a Seated Position
[See subsections ...]
-
Transfer Surface (M301.2 and M302.2)
The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids transfer when moving onto and off of the equipment (see defined terms in...
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M302.4.1 or M302.4.2. ...
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M302.4.1 or M302.4.2....
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the seated position be usable with a patient lift and comply with either the proposed clearance in base (proposed...
- Medical Accessibility LLC
-
I. BACKGROUND
The Plaintiffs’ allegations in the DRC/ERC Litigation include, among other things, not being placed in an accessible inpatient room; being examined on inaccessible equipment which required...
-
PURPOSE AND LEGAL AUTHORITY
Examples of ICT include computers, information kiosks and transaction machines, telecommunications equipment, multifunction office machines, software, websites, and electronic documents....
-
Tips for Weighing People Using an Accessible Scale
By June Isaacson Kailes, Associate Director Harris Family Center for Disability and Health Policy Western University of Health Sciences, Pomona, California Update -...
-
236 and 1004 Exercise Machines and Equipment
[See subsections ...]
-
M302.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in a seated position of 17 inches minimum and 19 inches maximum....