Emergency communication shall comply with Section 11B-407.4.9.
Search Results "Elevator Bank"
-
11B-411.4.9 Emergency communication
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section...
-
11B-411.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-411.4.8.2.
-
11B-1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface.
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum.
-
11B-1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated...
-
11B-409.4.7 Emergency communications
Emergency two-way communication systems shall comply with Section 11B-409.4.7.
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3.
-
11B-1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-411.4.9 Emergency communication
Emergency communication shall comply with Section 11B-407.4.9.
-
11B-411.4.10 Support rail
Support rails complying with Section 11B-407.4.10 shall be provided on at least one wall of the car.
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3.
-
11B-411.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-411.4.8.2.
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section...
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated...
-
11B-409.4.7 Emergency communications
Emergency two-way communication systems shall comply with Section 11B-409.4.7.
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface.
-
11B-411.4.6.2 Buttons
Car control buttons shall comply with Sections 11B-407.4.6.2.1 and 11B-407.4.6.2.4. The car shall not have non-functional, exposed floor buttons.