5. Does the accessible toilet in each accessible guestroom bathroom have a horizontal grab bar along the wall behind the toilet that is at least 36" long and mounted 33"-36" above...
Search Results "Counter Height"
Commonly Searched Documents
-
5. Grab Bars
-
1134A.8, Item 1
1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for...
-
§ 38.75(c)
(c) Characters on signs required by paragraphs (a) or (b) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10,...
-
M305.2.3 Height (Section-by-Section Analysis)
In the MDE NPRM there was no specific requirement regarding the height of the transfer support, only that it be “within reach” of the patient (proposed M305.2.1)....
-
Example 1: With Cooking Facilities
Example The break room shown in the illustration has a counter, sink, built-in cooking facility (microwave), and storage....
-
804.3 Kitchen Work Surface (Exception)
804.3 Kitchen Work Surface (Exception) This section requires at least one work surface to be provided at kitchen counters in residential dwelling units required to provide mobility features...
- UpScale by Medical Accessibility - Adjustable Height Exam Table with Built-in Scale
-
11B-703.5.6 Height from finish floor or ground
11B-703.5.6 Height from finish floor or ground. Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1....
-
11B-216.2 Designations
at the door to the space that they serve, but this is inferable from the fact that the requirement for braille is contained within 11B-703.2, as are the requirements pertaining to the height...
-
Identification: ADA Standard Section 502.6
Section 502.6 covers the current ADA Standards for parking space identification signs.
-
Characters: ADA Standard Section 707.7.2
Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I". Characters shall contrast...
-
5.4.3 Transfer Support Height for M301 and M302
The purpose of a minimum height is to ensure that the gripping surface is at an adequate height to facilitate positioning during a transfer....
-
Food and Restaurant Services
There must be an accessible route to all dining areas, including raised or sunken dining areas and outdoor dining areas, as well as to food service lines, service counters, and public restrooms...
-
607.4.2.1 Back Wall
607.4.2.1 Back Wall. Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm)...
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim...
-
407.4.8.1.1 Size
Characters shall be ½ inch (13 mm) high minimum.
-
607.4.1.1 Back Wall
607.4.1.1 Back Wall. Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm)...
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum...
-
11B-407.4.8.1.1 Size
Characters shall be ½ inch (12.7 mm) high minimum.
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of...
-
Question 17
YES/NO 17. Are the signs for the accessible restrooms and fitting rooms still readable and mounted next to the latch side of the door, at 5 feet to...
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim...
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of...
-
Picnic Tables [1011.2 and 1011.4]
The number of wheelchair spaces that must be provided at each table is based on the usable table surface perimeter. At least one wheelchair seating space a minimum of 30 by 48...