Path-of-Travel (wheelchair) space allowances.xii In general, a 36” wide accessible route is needed with a slightly larger space provided at corners....
Search Results "Centered Clear Floor Space"
Commonly Searched Documents
-
2. a. iv. Path-of-Travel (wheelchair) space allowances
-
Clear Floor and Turning Space Inside Examination Rooms
The minimum amount of space required is 30 inches by 48 inches. Clear floor space is needed along at least one side of an adjustable height examination table....
- Access Board: Clear Floor Space Position
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
Vending Machines and Other Equipment [5.8]
Vending Machines and Other Equipment [5.8] Since vending machines often are not fixed, ADAAG only requires that clear space be available at them for a forward or side approach and that...
- Landscape Forms Inc. Sort Recycling Units
-
1009.2.3 Clear Deck Space
1009.2.3 Clear Deck Space. On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location. ...
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
-
Forward Reach [4.2.5]
Forward reaches are measured to the edge of available clear floor space. This accommodates high and low reaches and assumes some forward bending....
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
1134A.6, Item 1.2
A water closet may project a maximum of 12 inches (305 mm) into the opening, provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
Thus, for a bathroom, there must be sufficient maneuvering space and clear floor space so that a person using a wheelchair or other mobility aid can enter and close the door, use the fixtures...
-
1134A.6, Item 1.2
A water closet may project a maximum of 12 inches (305 mm) into the opening provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided....
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
Circular Space: ADA Standard Section 304.3.1
Section 304.3.1 covers the current ADA Standards for circular turning space.
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
Floor Designation: ADA Standard Section 407.2.3.1
Section 407.2.3.1 covers the current ADA Standards for elevator floor designations.
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
F224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3....
-
224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3....