The height of the breast platform shall be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when in use by a patient seated in a wheelchair....
Search Results "Sign Clear Floor Space"
-
M303.4.1 Breast Platforms
-
Handrail Extensions [§505.10]
Handrail Extensions [§505.10] Handrail extensions at the top and bottom must return to walls, guards, or floors and horizontal portions must comply as protruding objects....
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
1129B.3, Item 2
SECTION 1129B - ACCESSIBLE PARKING REQUIRED 1129B.3 Parking space size. ...
-
Program Accessibility
Examples A legislator’s local office is on the second floor of a building that doesn’t have an elevator....
- Interface Human Nature Collection HN820 Carpet Tiles
- Endorphin 325 Functional Wall Pulley
-
"Video Remote Interpreting" (VRI) Services (Section-by-Section Analysis)
The video phone provides video transmission to a video monitor that permits the individual who is deaf or hard of hearing to view and sign to a video interpreter (i.e., a live interpreter...
-
11B-407.4.7.1.2 Location
[2010 ADA Standards] EXCEPTION: Where space on an existing car operating panel precludes tactile markings to the left of the controls, markings shall be placed as near to the control...
-
11B-407.4.7.1.2 Location
[2010 ADA Standards] EXCEPTION: Where space on an existing car operating panel precludes tactile markings to the left of the controls, markings shall be placed as near to the control...
-
1009.10 Directional signage
indicating the location of all other means of egress and which of those are accessible means of egress shall be provided at the following: At exits serving a required accessible space...
-
1134A.2 Number of complying bathrooms
A minimum 18-inch (457 mm) clear maneuvering space shall be provided on the swing side of the door at the strike edge of the door. 9. ...
-
1134A.2 Number of complying bathrooms
A minimum 18-inch (457 mm) clear maneuvering space shall be provided on the swing side of the door at the strike edge of the door. 9....
- SignOn VRI in Legal Settings
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated loading to...
-
407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (13 mm) under rated loading to zero...
-
2b
Are all large showers free of curbs or lips at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...
-
K6
If food service lines are provided, is an accessible route provided (at least 36 inches wide) and are the tray slides no higher than 34 inches above the floor?...
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated loading to...
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated loading to...
- Panda TS.13 Aluminum/Wood Clad Thermally Broken Lift & Slide System
- Panda S.11 Aluminum/Wood Clad Lift & Slide System